SIPLACE X-Series (SIPLACE X-Series S, from SC 708.1) Edition 05/2015 EN User manual.pdf - 第348页
6 Station extensions User manual SIPLACE X-Series 6.1 Nozzle changer From software version 708.1 Version 05/2015 348 6.1.4.6 Configuration example: CPP for SIPLACE X4i S Locations 1, 2, 3 and 4 can each accommodate o ne …

User manual SIPLACE X-Series 6 Station extensions
From software version 708.1 Version 05/2015 6.1 Nozzle changer
347
6.1.4.5 Technical data
6
Nozzle changer for the SIPLACE MultiStar
Number of magazines
a*a
SIPLACE X2 S/X3 S/X4 S 6
SIPLACE X4i S 6
6
4
Number of nozzle holders
SIPLACE X2 S/X3 S/X4 S 6
SIPLACE X4i S 6
78
48
Standard configuration
SIPLACE X2 S/X3 S/X4 S 6
6
6
SIPLACE X4i S 6
5 magazines with 60 x 20xx nozzle garages
1 magazine with 9 x 28xx nozzle garages
3 magazines with 36 x 20xx nozzle garages
1 magazine with 9 x 28xx nozzle garages
Option: Nozzle changer "row 2" 4 magazines with 48 nozzle garages
Nozzle types 10xx, 11xx, 12xx
20xx, 28xx
*)a With restrictions at location 2 for MTC/WPC

6 Station extensions User manual SIPLACE X-Series
6.1 Nozzle changer From software version 708.1 Version 05/2015
348
6.1.4.6 Configuration example: CPP for SIPLACE X4i S
Locations 1, 2, 3 and 4 can each accommodate one nozzle changer for the CPP head (item 1 in
fig. 6.1 - 18
, page 348).
6
Fig. 6.1 - 18 Position of nozzle changer for the SIPLACE MultiStar machine - configuration example (SIPLACE X4i S)
6
6
(1) Nozzle changer
(2) SIPLACE MultiStar
(3) Stationary cameras
(4) Nozzle changer row 2 (optional)
PLEASE NOTE
Stop machine if magazine missing
The safety circuit stops the machine if magazines are missing or not fitted correctly.
Use all magazine places.
(2)(1)
(1)
(2)
(1)
(2) (2)
(3)
(3)
(1)
(4)
(4)

User manual SIPLACE X-Series 6 Station extensions
From software version 708.1 Version 05/2015 6.1 Nozzle changer
349
6.1.4.7 Configuration example: CPP for SIPLACE X4 S
Locations 1, 2, 3 and 4 can each accommodate one nozzle changer for the CPP head (item 1 in
fig. 6.1 - 19
, page 349).
6
Fig. 6.1 - 19 Position of nozzle changer for the SIPLACE MultiStar machine - configuration example (SIPLACE X4 S)
6
6
(1) Nozzle changer
(2) SIPLACE MultiStar
(3) Stationary cameras
(4) Nozzle changer row 2 (optional)
PLEASE NOTE
Stop machine if magazine missing
The safety circuit stops the machine if magazines are missing or not fitted correctly.
Use all magazine places.
(2)(1)
(1)
(2)
(1)
(2) (2)
(3)
(3)
(1)
(4)
(4)