CMV12000_DS000603_6-00.pdf - 第72页
Document Feedback CMV12000 Register Description Datasheet • PUBLIC DS000603 • v6 - 00 • 2023 -Sep- 22 84 │ 71 8 Register Description 8.1 Register Categories The registers are grouped i nto various categories, based on wh…

Document Feedback
CMV12000
Functional Description
Datasheet • PUBLIC
DS000603 • v6-00 • 2023-Sep-22
84 │ 70
Figure 95:
ADC Range Multiplication
ADC_range_mult2
ADC_range_mult
0
ADC_range_mult
1
ADC_range_mult
3
0
×1
×2
×4
1
N/A
N/A
×8
3
N/A
N/A
×16
Figure 96:
ADC Range Settings
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
260
100 150 200 250 300 350 400 450 500 550 600
ADC_Range Setting [ ]
LVDS Input CLK [MHz]
8b_mult_x1
10b_mult_x2
12b_mult_x4
8b_mult_x4
10b_mult_x8
12b_mult_x16

Document Feedback
CMV12000
Register Description
Datasheet • PUBLIC
DS000603 • v6-00 • 2023-Sep-22
84 │ 71
8 Register Description
8.1 Register Categories
The registers are grouped into various categories, based on when they may (or not may) be updated
and synced. The table below explains the details of the various categories.
Figure 97:
Register Categories
Category
Description
-
Register without category that can be uploaded at any time, but might directly influence the
sensor execution.
SYNC
Registers are internally synchronized to the end of FOT, so the read out will be done with these
registers applied.
Registers can only be uploaded during IDLE or FOT.
FRAME
Registers will be internally synced at FRAME_REQ.
Registers can only be uploaded during IDLE.
INTE
Registers will be internally synced at start of INTE.
Registers can only be uploaded during IDLE or FOT.
DC
Registers will be internally synced immediately.
Registers can only be uploaded during IDLE or FOT.
IDLE
Registers will be internally synced immediately.
Registers can only be uploaded when the sensor is IDLE.
RO
Registers can be read only.
8.2 Register Overview
Below is an overview of all registers, together with their default value after reset/startup. Some
registers have to be changed to another fixed value after reset/startup, independent on the sensor
control or modes. This value is in the last column.
Figure 98:
Register Overview
Address
Register Name(s)
Category
Default Value
Fixed Value
0
-
0
1
Number_lines_tot[15:0]
SYNC
3072
2
Y_start_1[15:0]
SYNC
0
3
Y_start_2[15:0]
SYNC
0
4
Y_start_3[15:0]
SYNC
0

Document Feedback
CMV12000
Register Description
Datasheet • PUBLIC
DS000603 • v6-00 • 2023-Sep-22
84 │ 72
Address
Register Name(s)
Category
Default Value
Fixed Value
5
Y_start_4[15:0]
SYNC
0
6
Y_start_5[15:0]
SYNC
0
7
Y_start_6[15:0]
SYNC
0
8
Y_start_7[15:0]
SYNC
0
9
Y_start_8[15:0]
SYNC
0
10
Y_start_9[15:0]
SYNC
0
11
Y_start_10[15:0]
SYNC
0
12
Y_start_11[15:0]
SYNC
0
13
Y_start_12[15:0]
SYNC
0
14
Y_start_13[15:0]
SYNC
0
15
Y_start_14[15:0]
SYNC
0
16
Y_start_15[15:0]
SYNC
0
17
Y_start_16[15:0]
SYNC
0
18
Y_start_17[15:0]
SYNC
0
19
Y_start_18[15:0]
SYNC
0
20
Y_start_19[15:0]
SYNC
0
21
Y_start_20[15:0]
SYNC
0
22
Y_start_21[15:0]
SYNC
0
23
Y_start_22[15:0]
SYNC
0
24
Y_start_23[15:0]
SYNC
0
25
Y_start_24[15:0]
SYNC
0
26
Y_start_25[15:0]
SYNC
0
27
Y_start_26[15:0]
SYNC
0
28
Y_start_27[15:0]
SYNC
0
29
Y_start_28[15:0]
SYNC
0
30
Y_start_29[15:0]
SYNC
0
31
Y_start_30[15:0]
SYNC
0
32
Y_start_31[15:0]
SYNC
0
33
Y_start_32[15:0]
SYNC
0
34
Y_size_1[15:0]
SYNC
0
35
Y_size_2[15:0]
SYNC
0
36
Y_size_3[15:0]
SYNC
0
37
Y_size_4[15:0]
SYNC
0
38
Y_size_5[15:0]
SYNC
0
39
Y_size_6[15:0]
SYNC
0
40
Y_size_7[15:0]
SYNC
0
41
Y_size_8[15:0]
SYNC
0
42
Y_size_9[15:0]
SYNC
0
43
Y_size_10[15:0]
SYNC
0
44
Y_size_11[15:0]
SYNC
0