M3plus_OperationManual_e.pdf - 第116页

3 - 51 4. Creating the component information 3 Creating the PCB data 6 Set "Position Definition" of the Pick parameters. Set this parameter to "Automatic" when using a stick feeder. n NOTE The "P…

100%1 / 267
3 -50
3
Creating the PCB data
4. Creating the component information
4
Set "Feeder Type" of the Basic parameters.
Set "Feeder Type" according to the stick feeder type you will use.
Select "Feeder Type".
Select "Feeder Type".
27433-5E-20
High-speed stick feeder
Select from among "HS-Stick-L06", "HS-Stick-L09", "HS-Stick-L13", "HS-Stick-L16", "HS-Stick-
L20" and "HS-Stick-L26". (Each number indicates the length of the component.) For other high-
speed stick feeders, select from "HS-Stick-A" to "HS-Stick-D".
Stacked stick feeder
Select from among "StackStk-L06", "StackStk-L09", "StackStk-L13", "StackStk-L16", "StackStk-
L20" and "StackStk-L26". (Each number indicates the length of the component.) For other stacked
stick feeders, select from "StackStk-A" to "StackStk-D".
n
NOTE
Stack stick feeders can only be used with machines designed for large tape feeders. Mutli-stick feeders are not
supported.
5
Set "Feeder Set No." of the Pick parameters.
Enter the number of the feeder set position at which the stick feeder knockpins are
inserted into the feeder plate.
Enter the feeder set position.
Enter the feeder set position
27434-5E-20
3 -51
4. Creating the component information
3
Creating the PCB data
6
Set "Position Definition" of the Pick parameters.
Set this parameter to "Automatic" when using a stick feeder.
n
NOTE
The "Position Definition" parameter specifies the method for obtaining the coordinates of a component pickup
position.
When "Automatic" is selected, the machine automatically calculates the pickup position based on the feeder plate
reference position. Select this setting when using components whose pickup position is independent of the
component size, such as tape feeders.
7
Set the Tray parameters.
Open the Tray tab screen and set each parameter as follows.
Comp. Amount:
Enter the number of components loaded into a single stick.
Current Pos.:
This shows the number of components which have been used from the stick. Use
the initial setting value.
CountOut Stop:
Normally, set this parameter to "Nothing". If this is set to "Exist", the machine will
automatically stop when the number of components set in the Comp Amount
parameter have been used up.
Tray parameter setting
27437-5E-20
3 -52
3
Creating the PCB data
4. Creating the component information
8
Set the data optimization.
Open the Option tab screen, and set "Use Feeder Optimize" to "Yes" or "No".
Set to "Yes" when optimizing the feeder set positions after creating the PCB data.
Set to "No" when not optimizing the feeder set positions after creating the PCB data
(to set the feeder should at a particular position).
"Use Feeder Optimize" parameter setting
27438-5E-20
n
NOTE
When the stick feeder needs to be installed at a particular position, you cannot make off-line settings. Be sure to
use teaching to enter the correct pickup point.