M3plus_OperationManual_e.pdf - 第42页

2 - 9 2 Basic oper ation 3. Starting and stopping the machine 3.2 Starting the machine Proceed as follows to start the machine. 1 Turn the main power ON. Turn on the main power switch at the front lower right of the mach…

100%1 / 267
2 -8
2
Basic operation
3. Starting and stopping the machine
3.1 Inspection before operation
The table below shows checkpoints you should make before turning the power on.
w
WARNING
ALWAYS BE SURE TO PRESS THE EMERGENCY STOP BUTTON BEFORE MAKING
INSPECTION.
Checkpoint
Checkpoints before operation
Air
Power supply
Safety cover
Feeder
Conveyor
Head
Nozzle
Check that the black needle on the pressure gauge reads 0.55MPa.
Open the front cover of the machine and check that the specified power is connected to the
power terminal block.
Check that all covers are closed.
Check that each feeder is securely installed to the feeder plate and is not
floating.
Check that there is no foreign matter or debris on the feeders.
Check that no foreign matter or debris is on the conveyor.
Check that no parts of the conveyor unit interfere with each other such as the push-up pins
and conveyor rails.
Check that each nozzle is correctly installed to the head.
Check that the nozzle tips are not nicked, solder does not adhere to the nozzle tips,
and nozzle spring-action is smooth.
25203-5E-20
w
WARNING
THE SIGNAL LIGHT (OR WARNING LAMP) IS AN IMPORTANT DEVICE THAT INDICATES THE
MACHINE STATUS. BEFORE BEGINNING ANY OPERATION, BE SURE TO CHECK THAT THE
SIGNAL LIGHT SHOWS THE CORRECT MACHINE STATUS AS FOLLOWS:
GREEN: MACHINE IS IN AUTOMATIC OPERATION.
YELLOW: ERROR OR INTERLOCK HAS OCCURRED.
RED: MACHINE IS IN EMERGENCY STOP.
NEVER ALLOW ANY PART OF THE BODY OR ANY OBJECT TO ENTER THE MOVEMENT
RANGE OF THE HEAD ASSEMBLY WHILE THE GREEN LAMP IS LIT.
2 -9
2
Basic operation
3. Starting and stopping the machine
3.2 Starting the machine
Proceed as follows to start the machine.
1
Turn the main power ON.
Turn on the main power switch at the front lower right of the machine, by turning it
to the right. The Initialization screen appears and the loading of the program
necessary for machine operation starts.
ON
OFF
Main switch
21201-5E-20
Initialization screen
27205-5E-20
2
Perform return-to-origin.
After initialization, the return-to-origin dialog box appears. Follow the instructions on
the screen.
2 -10
2
Basic operation
3. Starting and stopping the machine
3
Press the [Operator] button.
The ID WINDOW dialog box appears for specifying the operator.
Press the [Operator] button to open the ID WINDOW.
[Operator] button
27206-5E-20
4
Specify the operator and enter the password.
When the password is matched, the initial screen (Setup screen before selecting a
PCB) appears.
Select the operator and press [OK].
Specifying the operator
27207-5E-20
Reference
Active menu buttons differ depending on the operation level setup. For example, when the machine is turned on
with the factory setup, the program starts up at an operation level called "Default Operator". This "Default
Operator" level is set to "Level 0" at the time of shipment to allow only basic operation items. This operation
level can be changed as needed. Operators and operation items can also be added and specified by setting the
password and operation level.