2 - 11 2 Basic oper ation 3. Starting and stopping the machine 3.3 Starting and warming up the machine After starting up the machine, we recommend warming it up for about 10 minutes in most cases. If less than two hours …

2 -10
2
Basic operation
3. Starting and stopping the machine
3
Press the [Operator] button.
The ID WINDOW dialog box appears for specifying the operator.
Press the [Operator] button to open the ID WINDOW.
[Operator] button
27206-5E-20
4
Specify the operator and enter the password.
When the password is matched, the initial screen (Setup screen before selecting a
PCB) appears.
Select the operator and press [OK].
Specifying the operator
27207-5E-20
Reference
Active menu buttons differ depending on the operation level setup. For example, when the machine is turned on
with the factory setup, the program starts up at an operation level called "Default Operator". This "Default
Operator" level is set to "Level 0" at the time of shipment to allow only basic operation items. This operation
level can be changed as needed. Operators and operation items can also be added and specified by setting the
password and operation level.

2 -11
2
Basic operation
3. Starting and stopping the machine
3.3 Starting and warming up the machine
After starting up the machine, we recommend warming it up for about 10 minutes in most
cases. If less than two hours has elapsed after the machine was last used, no warm-up is
necessary.
1
Make pre-operation checks and then start up the machine.
For pre-operation checks and starting up the machine, see "3.1 Inspection before
operation" in this chapter.
2
Press the [Warm Up] button on the Setup screen.
The Warm-up screen then appears.
3
Enter a warm-up time.
Press the [Stop after time over] button and enter the warm-up time. Warm-up will
automatically stop when the warm-up time you set has elapsed. Normally, a warm-up
time of about 10 minutes is recommended.
[Warm Up] Button
Setup screen
Warm-up time setting screen
Press this button
to set warmup time.
27301-5E-20

2 -12
2
Basic operation
3. Starting and stopping the machine
4
Press the [Start] button to start warm-up.
The warm-up progress time and bar will appear on the Warm-up screen.
Warm-up screen
27302-5E-20
c
CAUTION
If an abnormality occurs during warm-up, press the [Stop] button to stop operation
immediately, check the cause of the problem and eliminate it.
5
Finish the warm-up.
Warm-up will automatically stop when the warm-up time you set is reached. Press the