00197199-04_IM_WLAN-Infrastructure.pdf - 第28页
Components Siemens SCALANCE W788-1Pro Access Point 3.3.3 Configuration 28 Installation Manual WLAN Infrastructure for SIPLACE ► Define the WLAN security settings. ► For the SIPLACE app lications, select Security Level an…

Components
3.3.3 Configuration Siemens SCALANCE W788-1Pro Access Point
Installation Manual WLAN Infrastructure for SIPLACE 27
► Enter the network name of your radio cell in the SSID field. To hide this, click on Enable Closed Wire
-
less System feature.
► For intracell mode, select Enable Intracell communication from the drop down list and then click on
the entry Allowed.
► Click on Next. You will see the next input mask.
CAUTION
Intracell mode must be enabled
If this setting is not enabled, communication between the MC70 and W744 client module will
not be possible.

Components
Siemens SCALANCE W788-1Pro Access Point 3.3.3 Configuration
28 Installation Manual WLAN Infrastructure for SIPLACE
► Define the WLAN security settings.
► For the SIPLACE applications, select Security Level and the entry High (WPA-PSK) from the drop-
down list. Then select the encryption option Cipher and the entry TKIP from the drop-down list.
► Click on Next. You will see the next input mask.
► Further settings are now necessary, depending on the security mode you have chosen. WPA-PSK
requires the entry of a communication password, which is then cyclically changed during communi
-
cation, to prevent unauthorized decoding.
► Enter a character string with at least 8 characters in the Pass phrase field. The more complex the
character string is, the more secure data encryption will be.
► Repeat your entry in the Pass phrase confirmation field.
► Click on Next. You will see the next input mask.
CAUTION
WPA-PSK
If WPA-PSK is not available, configure the setting.

Components
3.3.3 Configuration Siemens SCALANCE W788-1Pro Access Point
Installation Manual WLAN Infrastructure for SIPLACE 29
► At the end of the Security Wizards process, you will see a summary of your settings.
► Click on Next. You will see the next input mask.
► Click on the Finish button. Once again, you need to restart the access point to activate your new set
-
tings. This can be performed at System → Restart.