YSM20R_YSM20WR_Mainte_E.pdf - 第70页

3-9 3 Periodic maintenance items n How to use ANC nozzle attaching/detaching tool (storing) Attach nozzles at the nozzle station in the reverse order of detac hing. 1 Check the nozzle setting position. Check that other n…

100%1 / 207
3-8
3
Periodic maintenance items
n
How to use ANC nozzle attaching/detaching tool (detaching nozzles)
1
Open the nozzle station shutter.
Open the [Unit] - [Head] screen and press
the [Nozzle. Stn Shutter] button to open the
nozzle station shutter.
2
Set the tool on the nozzle station.
1. Press the emergency stop button and
then open the machine safety cover.
2. Set the tool vertically on the nozzles at
the nozzle station aligning the position of
nozzles to be detached.
3. Check that the tool is set to nozzles
securely.
3
Raise the tool up.
Raise the tool up vertically and slowly.
n
NOTE
Raise the tool up vertically and slowly to avoid the
nozzle tip from hitting the shutter, etc.
c
CAUTION
If raising the tool up fast and forcibly, nozzles or the
nozzle station may be damaged.
4
Close the nozzle station shutter.
Press the [Nozzle. Stn Shutter] button again
and close the nozzle station shutter.
Nozzle station - Opening the shutter
Step1
54300-KMK-00
Setting the tool
Step 2
Set the tool vertically aligning
nozzles to be detached.
Check that the tool is set to
nozzles securely.
53311-KMK-00
Raising the tool up
Step 3
Raise the tool up vertically to avoid the
nozzle tip from hitting the shutter.
53312-KMK-00
3-9
3
Periodic maintenance items
n
How to use ANC nozzle attaching/detaching tool (storing)
Attach nozzles at the nozzle station in the reverse order of detaching.
1
Check the nozzle setting position.
Check that other nozzles are not set to the nozzle storage position and the setting position is correct.
n
NOTE
Regarding the nozzle setting position, check the nozzle placement position label attached in the machine or the
machine setting.
2
Set the nozzles to the tool.
c
CAUTION
The positioning pins are in each nozzle storage position at the nozzle station to avoid setting the incorrect types of
nozzle and the incorrect nozzle setting direction. Take precautions about the nozzle setting position and the nozzle
setting direction when setting the nozzles to the tool.
3
Open the nozzle station shutter.
1. Press the emergency stop button and then open the machine safety cover.
2. Open the [Unit] - [Head] screen and press the [Nozzle. Stn Shutter] button to open the nozzle station
shutter.
4
Set the tool on the nozzle station.
1. Set the tool that the nozzles were set in Step 2 to the relevant position of the nozzle station.
2. Check that the nozzles are set securely to the nozzle station.
5
Close the nozzle station shutter.
Press the [Nozzle. Stn Shutter] button again and close the nozzle station shutter.
6
Raise the tool up.
Raise the tool up vertically and slowly and detach the nozzles from the tool.
n
NOTE
Raise the tool up vertically and slowly to avoid the nozzle tip from hitting the shutter, etc.
c
CAUTION
If raising the tool up fast and forcibly, nozzles or the nozzle station may be damaged.
3-10
3
Periodic maintenance items
1.3 Cleaning and lubricating gripper nozzle (option)
The gripper nozzle that mounts a connector, etc. requires the periodic inspection and lubricating.
n
NOTE
The gripper nozzle is used to pick up a special shape component. Select and special order a gripper nozzle fitting the
component shape.
1.3.1 Inspecting gripper nozzle
n
Checking the gripper nozzle condition
Move the grip of the nozzle with a finger. If it moves smoothly, there is no problem. If it moves back unsteadily
or is stuck in, the component pickup error or the recognition error may occur. Clean and lubricate the gripper
nozzle referring to the next page "1.3.2 Cleaning and lubricating gripper nozzle".
Additionally, check that no wear or dirt is found in the grip or operation part. If the grip is worn out, replace
the nozzle.
Inspecting gripper nozzle
Example: Type30ALD nozzle
Grip is not worn out.
No dirt or dust is found.
Grip moves smoothly.
53313-KMK-00
1.3.2 Cleaning and lubricating gripper nozzle
e
1
Remove nozzles.
1. Press the emergency stop button and
then open the machine safety cover.
2. Remove nozzles from the head. If the
machine is equipped with the nozzle
station, press the [Nozzle. Stn Shutter]
button to open the nozzle station shutter
and remove nozzles.
2
Clean the nozzle operation part.
If dust is in the gripper nozzle operation part,
remove it with an air blow tool (option), etc.
Air blow
Step2
Air blow tool
53314-KMK-00