00196497-07_SM_SXDX12_en.pdf - 第109页
Service Work Conveyor 3.4.16 Replacing the X Trailing Cable Vacuu m [03075585-xx] Gantries Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 109 Points to be secure d with Loctite 241 ► Having l oosened the screws indicate d i…

Service Work Conveyor
Gantries 3.4.16 Replacing the X Trailing Cable Vacuum [03075585-xx]
108 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
► Loosen and remove the hexagon bolts (1) for the bot-
tom clamp on the trailing cable.
► Remove the trailing cable (2) together with the vacu-
um distributor.
► Disconnect the two black hoses from the vacuum
distributor (1) and clean it with ethanol. The old hoses
are no longer suitable for use.
► Before connecting the new hoses, clean the vacuum
connection of the trailing cable (2) with ethanol.
► Plug the new hoses into the vacuum distributor and
the vacuum connection of the new trailing cable.
The top hose [03075884-xx] is 132 mm long.
The bottom hose [03075885-xx] is 125 mm long.
These are not included in the spare parts set for the
trailing cable.
► Remove unnecessary ethanol (3).
► If necessary, disassemble the two pushbuttons ((1)
assembled, (2) disassembled, Phillips screwdriver
size 2) on the old trailing cable and fit them to the new
trailing cable. Use the original screws with a length of
4 mm, because otherwise the hoses can be dam-
aged.
Pushbutton parts:
▪ Spring component SFD3400 [03012472-xx]
▪ Spacer [03078158-xx]
▪ Screws ISO7046-2-M2.5x4-A2-70-H [03023226-xx],

Service Work Conveyor
3.4.16 Replacing the X Trailing Cable Vacuum [03075585-xx] Gantries
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 109
Points to be secured with Loctite 241
► Having loosened the screws indicated in the graphic, apply some Loctite 241 to the M4 threads and
retighten the screws.
► Replace the new trailing cable and fix it with the top
and bottom hexagon bolts. Do not forget the plates.
Carefully thread the flat ribbon cable through the
opening on the board holder. Make sure not to dam-
age the cables.
► (1) Fasten the vacuum distributor and the vacuum
connection. Use the two screws ISO4762-M3x40-
A2-70 [03043115-xx] and the shim plates DIN7985-
M3x3-A2-Z [00368583-xx] for the vacuum connec-
tion. Screw the mounting plate and the vacuum con-
nection to the board holder. Secure the screws of the
vacuum distributor with Loctite 241 (2).
CAUTION!
There are M3 press-in nuts on the head mount.
Press the screws against the nuts with only a little force.
CAUTION
Observe the current Loctite 241 safety data sheet by all means!
CAUTION
Leaky connection
The four-fold air supply hose cannot be glued in place until the trailing cable and the distributor
on the board holder have been assembled. Otherwise the connection could be damaged and
become leaky.
► For this reason, never open the hexagon bolts and the screws of the vacuum connection
on the top trailing cable if this is not absolutely necessary.

Service Work Conveyor
Gantries 3.4.16 Replacing the X Trailing Cable Vacuum [03075585-xx]
110 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
► Assemble the Vision board spread spectrum in reverse order and reconnect the cables for compo-
nent camera, PCB camera and CAN bus. Also assemble the corresponding cable holders. (See also
"3.4.9 Replacing the Vision Board Spread Spectrum HCU [03067289-xx]" [ ➙ 94])
► Plug the flat ribbon cables of the trailing cable into the Vision board spread spectrum and the head
interface.
► Reconnect the hoses for the head to the vacuum distributor.
► Reconnect all electrical connections of the trailing cable to the gantry interface X. (See also "3.4.4
Replacing the Gantry InterfaceX [03065078‑xx]" [ ➙ 88])
See also
3.4.5 Replacing the Gantry InterfaceY [03065335‑xx] [ ➙ 90]
CAUTION!
Observe the current Loctite 406 safety data sheet by all
means!
► The hoses of the trailing cable must be secured with
the thin fluid Loctite 406 instant adhesive in the dis-
tributors.
Please use the dosage tip supplied. Make sure that a
thin adhesive film is laying around the hose. For this,
apply the adhesive directly on the interface between
distributor and hose. The adhesive is drawn into the
gap between hose and distributor by means of capil-
lary attraction.
Repeat this procedure for each individual hose as
well as for the four-fold air supply hose from the trail-
ing cable into the vacuum connection.