00196497-07_SM_SXDX12_en.pdf - 第270页

Settings Gantry Settings 4.4.5 Calibrating the X Axis 270 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 4.4.5 4 . 4 . 5 C a lib r a t in g t h e X A x is Calibrating the X Axis Overview The control parameters for the X a x…

100%1 / 334
Settings
4.4.4 GCU (Up to Machine Nos.: Mxxx) Gantry Settings
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 269
4.4.4
4.4.4 GCU (Up to Machine Nos.: Mxxx)
GCU (Up to Machine Nos.: Mxxx)
GCU - front side
GCU - rear side
Settings
Gantry Settings 4.4.5 Calibrating the X Axis
270 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
4.4.5
4.4.5 Calibrating the X Axis
Calibrating the X Axis
Overview
The control parameters for the X axis depend, for example, on the installation site, frame and head types.
The parameters therefore need to be calibrated on site.
Procedure
4.4.6
4.4.6 Calibrating the Y Axis
Calibrating the Y Axis
Overview
The SX1/SX2/DX1/DX2 machines use "H gantries" for the Y axis. These consist of two opposite drives
with their own control and an encoder (scale and read unit). For correct position regulation, encoder cal-
ibration must be performed on initial operation and after any modifications.
Procedure
Switch over to the operator level Service (Customer).
Switch over to the Service menu and select Ma-
chine calibration.
Select 3. X axis parameterization and click on Next.
Switch over to the operator level Service (Customer).
Switch over to the Service menu and select Ma-
chine calibration.
Select 1. Y axis encoder alignment and click on Next.
Now perform machine calibration, including mapping.
Settings
4.5.1 Setting the Nozzle Changer Height (DLM, C&P20, CPP, TH) Nozzle Changer Setting
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 271
4.5
4.5 Nozzle Changer Setting
Nozzle Changer Setting
4.5.1
4.5.1 Setting the Nozzle Changer Height (DLM, C&P20, CPP, TH)
Setting the Nozzle Changer Height (DLM, C&P20, CPP, TH)
Parts, equipment and tools
NC shim plate [03021079-xx]
NC support plate [03021044-xx]
Screws DIN 965-M4 x 10-4.8 [00095312-xx]
Setting
4.5.2
4.5.2 Setting the Height of the Nozzle Reject Station (DLM, C&P20, CPP)
Setting the Height of the Nozzle Reject Station (DLM, C&P20, CPP)
Parts, equipment and tools
Shim plates for nozzle reject device [03039514-xx]
Setting
The distance (1) between the contact surface of the
reject unit and the guide rail of the gantry needs to be
199.8 +/-0.2 mm.
You may need to use shim plates to adjust this.
The distance (1) between the contact surface of the
nozzle reject station and the guide rail of the gantry
needs to be 189 +0.1/-0.3 mm.