Service Work Conveyor COT insert 3.10.2 Replacing the SX1/SX2 Component Trolley Feed D evice Assembly 214 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 ► After pulling the table in throu gh the cylinder, the downholder p i…

100%1 / 334
Service Work Conveyor
3.10.2 Replacing the SX1/SX2 Component Trolley Feed Device Assembly [03059353-xx] COT insert
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 213
Checking the downholder positions
Move the component trolley back into the machine.
The component trolley height must be adjusted so that the side rails fit into the recess on the docking
aid (1). (See also "4.8.1 Setting the Changeover Table Height" [ ➙ 292])
1Docking aid
Service Work Conveyor
COT insert 3.10.2 Replacing the SX1/SX2 Component Trolley Feed Device Assembly
214 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
After pulling the table in through the cylinder, the downholder pin (1) should be up, against the com-
ponent trolley downholder (2).
1 Downholder pin on the docking aid 2 Component trolley downholder
NOTICE
Wear
In the event of frequent component trolley cycle changes, these parts may become worn. Both
the downholder pin and the component trolley downholder are available as spare parts.
Service Work Conveyor
3.10.3 Replacing the Feeder Unlocking Device 60-fold [03057772-xx] COT insert
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 215
3.10.3
3.10.3 Replacing the Feeder Unlocking Device 60-fold [03057772-xx]
Replacing the Feeder Unlocking Device 60-fold [03057772-xx]
Parts, Equipment and Tools
SX1/SX2: feeder unlocking device 60-fold [03057772-xx] or
DX1/DX2: feeder unlocking device 60/2-fold [03082610-xx]
Overview
Removal
Switch off the machine and secure it to prevent unauthorized reactivation. Observe the instructions
in section "1.2 Preparatory Work..." [ 13].
Disconnect all electrical and pneumatic connections. You may want to mark their positions, to make
clear assignment easier later on.
Undo the two fastening screws and remove the feeder unlock device.
1. Feeder control unit (FCU)
2. Feeder unlock device (under the FCU)
3. Connector for flat ribbon cable
4. Fastening screws for feeder unlock device
If there is a WPC at the same location, perform the follow-
ing two steps as well:
Dismantle the WPC docking rail (1).
Dismantle the left side of the insert mechanism (2).
Remove the four fastening screws (3) on the under-
side and the two fastening screws on the top of the
tape duct.