00196497-07_SM_SXDX12_en.pdf - 第133页

Service Work Conveyor 3.5.5 Replacing the Twin/VHF Head Placement heads Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 133 Removal NOTICE! When using mod ules with undetach able screws (1), you may need to fit these screws …

100%1 / 334
Service Work Conveyor
Placement heads 3.5.5 Replacing the Twin/VHF Head
132 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
Conversion to another installation height
3.5.5
3.5.5 Replacing the Twin/VHF Head
Replacing the Twin/VHF Head
Parts, Equipment and Tools
Select the relevant placement head:
Twin Pick&Place module [03033628-xx]
Twin Pick&Place module THK R2 [03097485-xx]
Very High Force P&P head [00119813-xx]
Very High Force Twin head [00119814-xx]
Twin VHF [03096701-xx]
Torque screwdriver 1-5 Nm [03078400-xx]
Extension/straight TX20 [03073256-xx]
Extension/straight [03043440-xx]
Bit holder for Torque Vario-S screwdriver [03078706-xx]
Calibration tool version 3 [03010565-xx]
SXDX12V1V2 Only
If required, Camera view screen Twin-Head, SX1/2 [03079524-xx]
For additional work on the placement head:
Head assembly stand [03056231-xx
Service manual "TH/VHF head" [DE: 00197468-xx]. [EN: 00197469-xx].
Overview
The Twin VHF consists of two identical Twin segments, which are fitted at an angle of 180°.
1. Drilling for the fastening screw of the bushing in "head
at bottom" position
2. Drilling for the fastening screw of the bushing in "head
at top" position
3. Bushing
All four bushings and the holding bracket must either be
fixed in top or bottom position.
Proceed as follows when replacing the bushings:
Undo the fastening screws of the bushings.
Insert the bushings in the correct position and re-
tighten them.
Perform these steps for all four fastening bushings
and the holding bracket of the head.
NOTICE
Module 1 and 2
The removal procedure is described here for module 1 (left). Removal for module 2 (right) is the
same.
In the case of older Twin heads, you need to remove module 1 before you can remove
module 2. During installation, module 2 needs to be fitted before module 1.
In the case of newer Twin heads and all Twin VHF heads, the modules can be removed
and fitted individually.
Service Work Conveyor
3.5.5 Replacing the Twin/VHF Head Placement heads
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 133
Removal
NOTICE!
When using modules with undetachable screws (1), you
may need to fit these screws on the other side, depending
on the installation position.
NOTICE
Twin and Twin VHF head
Removal and installation of the Twin VHF head follows the same procedure as that for the Twin
head. Any differences will be explicitly indicated.
Switch off the machine, disconnect it from the power
supply and secure it to prevent unauthorized reacti-
vation. Observe the instructions in section "1.2 Pre-
paratory Work..." [ ➙ 13].
Move the gantry into a position which allows you best
access.
Unplug the pneumatic connection from the TwinHead
vacuum generator to the pneumatic distributor (1)
and the silencer.
Disconnect the exhaust air silicone hose from the
TwinHead vacuum generator (4).
Unplug the pneumatic connection from the pneumat-
ic distributor (1) to the TwinHead return cylinder.
Unplug the flat ribbon cable (2) from the head main
board (3) on the TwinHead.
Remove the camera screen (1). This is fastened with
two black screws (2).
NOTICE!
Only use these screws to fix the camera screen. This pre-
vents reflection when measuring components with the
stationary camera.
Service Work Conveyor
Placement heads 3.5.5 Replacing the Twin/VHF Head
134 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
If you need to perform further work on this head (e.g. replacing spare parts), fit the head to the head
mount [03056231-xx].
Installation
Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
See also
4.9.2 Calibration [ ➙ 294]
3.5.7 Installation Positions on the Head Plate [ ➙ 138]
4.9.2.2 Calibrating the Heads and Cameras (SW70x) [ ➙ 295]
Each module is fixed with four screws to the head plate
and is positioned with two pins.
Remove the four M4x14 fastening screws (1) with a
long Allen key.
Pull the module out of the locating pins.
CAUTION
Installation instructions
Fit the fastening screws on the other side of the module, if needed (see above).
Make a note of the force values for the new module. These force values can be found on
a label at the side of the module.
Make sure that the assembly position is correct.
Perform a head calibration.