00196497-07_SM_SXDX12_en.pdf - 第196页

Service Work Conveyor Manual table 3.9.4 Replacing the Locking La tch [03069205-xx] 196 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 3.9.4 3 . 9 . 4 R e p la c in g t h e L o c k in g L a t c h [ 0 3 0 6 9 2 0 5 - x x ] R…

100%1 / 334
Service Work Conveyor
3.9.3 Removing the Front Section of the Manual Table Manual table
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 195
Removal
Dismantle the back section of the manual table. (See "3.9.2 Removing the Back Section of the Man-
ual Table" [ ➙ 193])
Loosen the fastening screws of the feeder locking device and then remove the board.
Loosen the 4 screws fastening the front section.
Pull the module out of the locating pins. You may need to use a rubber mallet to help you.
Installation
Follow the removal instructions in reverse order for installation.
If there is a WPC at the same location, perform the follow-
ing two steps as well:
Dismantle the WPC docking rail (1).
Dismantle the left side of the insert mechanism (2).
Loosen the 4 fastening screws (3) on the underside
and the 2 fastening screws on the top of the empty
tape duct.
Dismantle the stoppers (1).
You may need to lower the cutter onto the support
plates (2). (See "3.11.1 Replacing the Cutter
[03063781Sxx]" [ ➙ 223])
Service Work Conveyor
Manual table 3.9.4 Replacing the Locking Latch [03069205-xx]
196 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
3.9.4
3.9.4 Replacing the Locking Latch [03069205-xx]
Replacing the Locking Latch [03069205-xx]
Please refer the instructions in section "3.7.4 Replacing the Locking Latch [03069205-xx]" [ ➙ 188].
See also
3.9.5.1 Operating the Unlocking Hook [ ➙ 198]
3.9.8 Replacing the Feeder Lock on the Manual Table [03082778-xx] [ ➙ 202]
3.9.5
3.9.5 Replacing the Feeder Control Unit (FCU)
Replacing the Feeder Control Unit (FCU)
Parts, equipment and tools
Select the correct spare part:
Rubber mallet
Overview
NOTICE
Only every second location can be occupied.
We recommend that you use 2x8 mm feeders.
If you are using single 8 mm feeders, the location next to the feeder will be left empty.
NOTICE
Remove the feeder
Also observe section "3.9.5.1 Operating the Unlocking Hook" [ 198].
Machine type Designation Item No.
DX4 FCU 03082687-xx
DX1/DX2 FCU 03082605-xx
Manual table (using example of DX1/DX2)
1. Centering bar
2. FCU
3. Front part
4. Fixture bar
5. Back part
Service Work Conveyor
3.9.5 Replacing the Feeder Control Unit (FCU) Manual table
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 197
Removal
Dismantle the back section of the manual table (see "3.9.2 Removing the Back Section of the Manual
Table" [ ➙ 193]).
Dismantle the front section of the manual table (see "3.9.3 Removing the Front Section of the Manual
Table" [ ➙ 194]).
Dismantle the feeder unlocking device and the FCU (see section "COT insert").
Installation
Follow the removal instructions in reverse order for installation.
See also
3.10.5 Replacing the Feeder Control Unit (FCU) [03059666-xx] [ 217]
3.10 COT insert [ ➙ 206]
If there is a WPC at the same location, perform the follow-
ing two steps as well:
Dismantle the WPC docking rail (1).
Dismantle the left side of the insert mechanism (2).
Loosen the 4 fastening screws (3) on the underside
and the 2 fastening screws on the top of the empty
tape duct.