Dip switch S2 [03055517-03]
5.2.6
5.2.6 Vision hotlink adapter [03050555-xx]
Vision hotlink adapter [03050555-xx]
03050555-01
LED [03050555-01]
Switch Status Signal name Description
S2.1 OFF HCU_CM_FPGA_IO_0 „S0“ (gantry coding), not used
S2.2 OFF HCU_CM_FPGA_IO_1 „S1“ (gantry coding), not used
S2.3 OFF RESET_HCU1 ON: Reset HCU!
S2.4 OFF COM_BOOT_HCU ON: set to boot mode
LED Color Status Description
D1 GN ON +12VDC
D8 RD ON CLKUSR error
D9 GN ON +5 VDC
D10 GN OFF CRC_ERR
Description of the Circuit Boards
5.3.1 TSP400 [03057341-xx] Conveyor
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 321
5.3
5.3 Conveyor
Conveyor
5.3.1
5.3.1 TSP400 [03057341-xx]
TSP400 [03057341-xx]
03057341-02
LED [03057341-02]
Switches and buttons
LED Color Status Signal name Description
H1 RD ON LED_FAIL Error
H2 GN ON LED_RUN Running (operation)
H3 YE ON LED_CAN1 CAN bus activity of machine
H4 YE ON LED_CAN2 CAN bus activity of conveyor lane 1/2
H5 GN ON P40V +40VDC voltage supply is present
H6 GN ON +24 V +24VDC voltage supply is present
S1 Reset XC167 (used for eSW development only)
S2 Reset XC167 (used for eSW development only)
S3 Configuration for single and dual conveyor
Description of the Circuit Boards
Conveyor 5.3.1 TSP400 [03057341-xx]
322 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
Button S1, S2 [03057341-02]
Dip switch S3 [03057341-02]
Jumper [03057341-02]
Jumper
Buttons Status Signal name Description
S1 When pressed /MR RESET
S2 When pressed /BSL BOOT
Switch Status Function
PCB conveyor configuration
Single conveyor Dual lane conveyor
lane 1
Dual lane conveyor
lane 2
S3.1 ON/OFF OFF OFF ON
S3.2 ON/OFF OFF ON OFF
S3.3 OFF -
S3.7 OFF -
S3.8 OFF Flash memory internal, ON: flash memory external
Stopper configuration
Electromagnetic stop-
pers installed, stoppers
feedback sensors in-
stalled
Electromagnetic stop-
pers installed, stopper
feedback sensors not
installed
Electromagnetic stoppers
not installed
S3.4 ON/OFF OFF ON OFF
S3.5 ON/OFF OFF OFF ON
S3.6 ON/OFF OFF OFF OFF
Jumper Status Description
JP1 2 - 3 CAN bus terminating resistor, machine: OFF
JP2 1 – 2 CAN bus terminating resistor, lane 1 – 2: ON
JP3 1 - 2 Voltage supply stopper: internal
JP1 2-3 Terminating resistor for CAN bus of machine: Off
JP2 1-2 Terminating resistor for CAN bus of conveyor lane 1 or 2: On
JP3 1-2 Trigger signal, stopper: Internal