00196497-07_SM_SXDX12_en.pdf - 第325页
Description of the Circuit Boards 5.3.2 TSP400E [03057342-xx] Conveyor Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 325 5.3.2 5 . 3 . 2 T S P 4 0 0 E [ 0 3 0 5 7 3 4 2 - x x ] TSP400E [03057342-xx] 03057342-01 Dip switch …

Description of the Circuit Boards
Conveyor 5.3.1 TSP400 [03057341-xx]
324 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
Connector
Fuses
Potentiometer
X1 Siemens interface, upstream station X21 Board sensor placement area
X2 Siemens interface, downstream station X22 Spare
X3 SMEMA interface, upstream station X23 Board sensor output area
X4 SMEMA interface, downstream station X24 Sensor conveyor side width adjustment
unit 1
X5 Power supply X25 Sensor conveyor side wall, width adjust-
ment unit 2
X26 Sensor cylinder width adjustment unit 1
X7 CAN bus to machine controller X27 Sensor cylinder width adjustment unit 2
X8 V24 interface for troubleshooting (debug) X28 Spare
X9 Interface to board TSP400E (optional) X29 Stopper Long Board Option coding (togeth-
er with X37)
X10 Motor for conveyor belt X30 Spare
X11 Width adjustment motor X31 Spare
X12 Motor, lifting table X32 Pneumatic valve width adjustment unit 1
X33 Pneumatic valve width adjustment unit 2
X14 CAN bus to conveyor lane X34 Spare
X15 Track signals, conveyor motor X35 Stopper, input area
X16 Track signals, width adjustment motor X36 Stopper, placement area
X17 Track signals, lifting table motor X37 Stopper Long Board Option (together with
X29)
X18 Brake, lifting table X38 Stopper, output area
X19 Programming interface for development X39 Spare
X20 Board sensor input area X40 Programming interface for development
F1 [03079942-xx] Miniature fuse
5x20 / T 2A / ceramic
T2A Fuse protection
24V
(sensors, control system supply)
F2 [03078843-xx] miniature fuse
5x20 / T 6.3A / ceramic
T6.3A Fuse protection
40V
(supply, drives)
F3 Self-healing SMD fuse Polyswitch set for 24 V (supply, lifting table brake), not
replaceable
P1 Setting the zero point of the control loop for the lifting table/conveyor belt/width adjustment motor
(needs to be performed only once
P2 by the manufacturer and is then sealed with locking varnish). The potentiometer will be dis-
pensed with in future
P3 and replaced with an eSW teach function.

Description of the Circuit Boards
5.3.2 TSP400E [03057342-xx] Conveyor
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 325
5.3.2
5.3.2 TSP400E [03057342-xx]
TSP400E [03057342-xx]
03057342-01
Dip switch S4 [03057342-01]
Switch Status Description
S4.1 OFF Reserved
S4.2 OFF Reserved
S4.3 OFF Reserved
S4.4 OFF Reserved
S4.5 OFF Reserved
S4.6 OFF Reserved
S4.7 OFF Reserved
S4.8 OFF Reserved

Description of the Circuit Boards
COT insert 5.4.1 Insert control [03079305-xx]
326 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
5.4
5.4 COT insert
COT insert
5.4.1
5.4.1 Insert control [03079305-xx]
Insert control [03079305-xx]
[03078869-02], part of [03079305-xx]
LED [03079305-02]
5.4.2
5.4.2 Connecting assy FCU [03059783-xx]
Connecting assy FCU [03059783-xx]
03059783-04
LED Color Status Signal name Description
LED1 GN ON S_DOCKED CO trolley docked