00196497-07_SM_SXDX12_en.pdf - 第44页

Service Work Conveyor Electrical System 3.2.6 Replacin g the In rush Current L imitation Board Transformer (A1) [03066830- 44 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 3.2.6 3 . 2 . 6 R e p la c in g t h e I n r u s h …

100%1 / 334
Service Work Conveyor
3.2.5 Replacing the AC/DC Converter (PS1) 25 V [03055232-xx] Electrical System
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 43
3.2.5
3.2.5 Replacing the AC/DC Converter (PS1) 25V [03055232-xx]
Replacing the AC/DC Converter (PS1) 25 V [03055232-xx]
Parts, equipment and tools
AC/DC converter DC24V/20A 3 phase, set to DC25V [03055232-xx]
Overview
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 13].
Unplug all connections to the module. You may want to mark their positions, to make clear assign-
ment easier later on.
To release the module, press the lever at the back of the module down and then pull the module off
the rail.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
1. AC/DC converter (PS1) 25 V
CAUTION
Installation instructions
Set the voltage to 25 V. (See "4.3.2 Setting the Voltage on the AC/DC Converters" [255])
Service Work Conveyor
Electrical System 3.2.6 Replacing the Inrush Current Limitation Board Transformer (A1) [03066830-
44 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
3.2.6
3.2.6 Replacing the Inrush Current Limitation Board Transformer (A1) [03066830-xx]
Replacing the Inrush Current Limitation Board Transformer (A1) [03066830-xx]
Parts, equipment and tools
Inrush current limitation board transformer [03066830-xx]
Overview
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 13].
Loosen the screws fastening the mesh cover and then remove the cover.
Unplug all connections to board A1. You may want to mark their positions, to make clear assignment
easier later on.
Loosen the screws fastening board A1 and then remove the board.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
1. Two boards are fitted above one another here.
Front: inrush current limitation board for transformer
(A1)
Behind: inrush current limitation board for servo (A2)
CAUTION
Installation instructions
Check the correct input voltage. (See "3.2.3 Checking the Input Voltage at the Inrush Cur-
rent Limitation Board (A1)" [ 41])
Check the correct jumper setting. (See "5.1.5 Inrush Current Limitation Board Transformer
(A1) [03066830-xx]" [ 310])
Service Work Conveyor
3.2.7 Replacing the Inrush Current Limitation Board Servo (A1) [03058951-xx] Electrical System
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 45
3.2.7
3.2.7 Replacing the Inrush Current Limitation Board Servo (A1) [03058951-xx]
Replacing the Inrush Current Limitation Board Servo (A1) [03058951-xx]
Parts, Equipment and Tools
Inrush current limitation board servo [03058951-xx]
Overview
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 13].
Loosen the screws fastening the mesh cover and then remove the cover.
Unplug all connections to board A1. You may want to mark their positions, to make clear assignment
easier later on.
Loosen the screws fastening board A1 and then remove the board.
Unplug all connections to board A2. You may want to mark their positions, to make clear assignment
easier later on.
Loosen the screws fastening board A2 and then remove the board.
Installation
Follow the removal instructions in reverse order for installation.
1. Two boards are fitted above one another here.
Front: inrush current limitation board for transformer
(A1)
Behind: inrush current limitation board for servo (A2)