00196497-07_SM_SXDX12_en.pdf - 第288页

Settings Conveyor Settings 4.6.6 Conveyor Width Calibration 288 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 4.6.6 4 . 6 . 6 C o n v e y o r W id t h C a lib r a t io n Conveyor Width Calibration ► Open the Service view. …

100%1 / 334
Settings
4.6.5 Calibrating the Motors in the Conveyor Conveyor Settings
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 287
4.6.5
4.6.5 Calibrating the Motors in the Conveyor
Calibrating the Motors in the Conveyor
If the motors for the automatic width adjustment or for the lifting tables are replaced, they need to be
calibrated via the software afterwards. This is necessary since each motor has a different zero point and
calibration is the only way to enter the correct zero point into the machine data.
Calibration
Start up the station.
Switch over to the activity level Service (Customer) (or better still)
Switch over to the service menu .
Select the Conveyor configuration button.
Select the Initiate conveyor parameters
button.
Use the button to select the required con-
veyor lane.
Calibrate the relevant motor by either clicking the Mo-
tor calibrationorWidth adjustment button in the Lifting
table section.
Settings
Conveyor Settings 4.6.6 Conveyor Width Calibration
288 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
4.6.6
4.6.6 Conveyor Width Calibration
Conveyor Width Calibration
Open the Service view.
Click on the Single calibration button.
Click on the Conveyor Lane 1 or Conveyor Lane 2 button.
Click on the Calibrate conveyor width... button. The dialog box Calibrate conveyor width will open.
Place a 100 mm wide board into the selected conveyor lane and click on the Increase (small step)
or Decrease (small step), buttons to set the conveyor width stepwise to the board width.
Click on the Cancel... button, to close the dialog box.
Open the Manual operations > Subsystems view.
Click on the Conveyor Lane 1 or Conveyor Lane 2 button, to switch over to the Manual operations >
Subsystems > Conveyor Lane x > Functions view.
Test whether the board can be transported smoothly through the machine, without problems.
Press the following buttons one after the other: Input section, placement section, intermediate sec-
tion, placement section and output section.
Click on the icon, to return to the Service > Manual operations > Conveyor Lane x view.
Click on the Calibrate conveyor width... button. The dialog box Calibrate conveyor width will open.
Click on the OK button. The dialog box will close and the conveyor width will be calibrated to the
board width.
Click on the Save machine data for conveyor
button, to save the data generated during calibration
in the machine data.
NOTICE
Calibration
Use a 100 mm wide board to calibrate the conveyor width.
Switch the dual conveyor between "fixed right" and "fixed left". This ensures that all convey-
or sides are calibrated.
Settings
4.6.7 Board Clamping Conveyor Settings
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 289
4.6.7
4.6.7 Board Clamping
Board Clamping
4.6.7.1
4.6.7.1 Setting the Board Clamping (Actuator)
Setting the Board Clamping (Actuator)
If the conveyor control issues the error Clamping error conveyor, you need to check the distance from
the lifting table actuator to the upper edge of the conveyor belt.
Parts, equipment and tools
Setting gauge for actuator [03049740-xx]
Terminal strip [03076699-xx]
Setting
Fit the terminal strip onto the long side of the setting gauge.
Loosen the screws fastening the actuator.
Attach the setting gauge to the conveyor side, as shown in the diagram.
Tighten the screws fastening the actuator. This sets the distance to 94.0 mm.
Repeat this setting at all actuators.
1. Distance of 94.0 mm from the lower edge of the actu-
ator to the upper edge of the conveyor toothed belt
2. Setting gauge
3. Actuator.
4. Loosen and tighten the screws fastening the actuator
through the hole provided in the gauge.