00196497-07_SM_SXDX12_en.pdf - 第197页

Service Work Conveyor 3.9.5 Replacing the Feeder Control U nit (FCU) Manual table Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 197 Removal ► Dismantle the back section of the manual table (see "3.9.2 Remo vin g the B…

100%1 / 334
Service Work Conveyor
Manual table 3.9.4 Replacing the Locking Latch [03069205-xx]
196 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
3.9.4
3.9.4 Replacing the Locking Latch [03069205-xx]
Replacing the Locking Latch [03069205-xx]
Please refer the instructions in section "3.7.4 Replacing the Locking Latch [03069205-xx]" [ ➙ 188].
See also
3.9.5.1 Operating the Unlocking Hook [ ➙ 198]
3.9.8 Replacing the Feeder Lock on the Manual Table [03082778-xx] [ ➙ 202]
3.9.5
3.9.5 Replacing the Feeder Control Unit (FCU)
Replacing the Feeder Control Unit (FCU)
Parts, equipment and tools
Select the correct spare part:
Rubber mallet
Overview
NOTICE
Only every second location can be occupied.
We recommend that you use 2x8 mm feeders.
If you are using single 8 mm feeders, the location next to the feeder will be left empty.
NOTICE
Remove the feeder
Also observe section "3.9.5.1 Operating the Unlocking Hook" [ 198].
Machine type Designation Item No.
DX4 FCU 03082687-xx
DX1/DX2 FCU 03082605-xx
Manual table (using example of DX1/DX2)
1. Centering bar
2. FCU
3. Front part
4. Fixture bar
5. Back part
Service Work Conveyor
3.9.5 Replacing the Feeder Control Unit (FCU) Manual table
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 197
Removal
Dismantle the back section of the manual table (see "3.9.2 Removing the Back Section of the Manual
Table" [ ➙ 193]).
Dismantle the front section of the manual table (see "3.9.3 Removing the Front Section of the Manual
Table" [ ➙ 194]).
Dismantle the feeder unlocking device and the FCU (see section "COT insert").
Installation
Follow the removal instructions in reverse order for installation.
See also
3.10.5 Replacing the Feeder Control Unit (FCU) [03059666-xx] [ 217]
3.10 COT insert [ ➙ 206]
If there is a WPC at the same location, perform the follow-
ing two steps as well:
Dismantle the WPC docking rail (1).
Dismantle the left side of the insert mechanism (2).
Loosen the 4 fastening screws (3) on the underside
and the 2 fastening screws on the top of the empty
tape duct.
Service Work Conveyor
Manual table 3.9.5 Replacing the Feeder Control Unit (FCU)
198 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
3.9.5.1
3.9.5.1 Operating the Unlocking Hook
Operating the Unlocking Hook
Parts, equipment and tools
Unlocking hook [03038882-xx]
Overview
Application
Unlocking hook for manual tables
In the event of an error, it is not possible to remove the X
feeders manually by just removing the table.
If the Feeder Control Unit (FCU) fails, the unlocking hook
can be used to manually remove the X feeders from the
table. You can then replace the FCU.
The unlocking hook is supplied in the service box with
each machine order.
1. Red marking - height mark to used tape chute, for un-
locking the feeder.
Guidance for unlocking hook
Once the manual table has been fully configured with
feeders, start to remove the feeders with the unlocking
hook. Start at track 1.
(1) Guide the unlocking hook downwards, between
the side wall of the table and the feeder at track 1, lev-
el with the feeder pickup window.
CAUTION!
Make sure that the tip of the hook (2) points to the FCU
(3).
Feeder unlocking device
If the red mark (1) on the unlocking hook is at the
same height as the upper edge of the used tape
chute, turn the hook by 90 degrees. The hook must
then engage between the feeder and the latch on the
table (2).
Press the unlocking hook down more (3) and remove
the feeder.
Repeat these steps for all other feeders.