Service Work Conveyor 3.4.8 Replacing the Power Cube Module on the Head Inter face Gantries Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 93 3.4.8 3 . 4 . 8 R e p la c in g t h e P o w e r C u b e M o d u le o n t h e H e …

Service Work Conveyor
Gantries 3.4.7 Replacing the Head Interface [03055072-xx]
92 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
3.4.7
3.4.7 Replacing the Head Interface [03055072-xx]
Replacing the Head Interface [03055072-xx]
Parts, Equipment and Tools
▪ MODULE/head interface C700B [03055072-xx]
Overview
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section What To Do Before Starting Servicing Work....
► If there is a cover above the boards, dismantle it.
► Unplug all connectors and cable ties on the head interface. You may want to mark their positions, to
make clear assignment or replacement easier later on.
► Dismantle the sensor module. To do this, undo the four fastening screws and the cable holder. Some
versions may include a protective sheet, which is also held with these screws.
► Remove the six screws and the cable holder on the head interface.
► Carefully pull the head interface towards the front. Make sure that the connectors on the head adapt-
er are not damaged.
Installation
► Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
NOTICE
C&P20 P
If you are converting to a C&P20 P, one prerequisite is function state -05 or higher for the head
interface.
► You find a complete list of the prerequisites in section Replacing the C&P20 P Head.
Boards on the Gantry
1. Vision board spread spectrum
2. Head adapter (here the version for the TwinHead with
two HCUs)
3. HCU
4. Head interface
5. Sensor module
CAUTION
Installation instructions
► Check the setting of the DIP switch.
(See "5.2.1 Head Interface C700B [03055072-xx]" [ ➙ 311])

Service Work Conveyor
3.4.8 Replacing the Power Cube Module on the Head Interface Gantries
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 93
3.4.8
3.4.8 Replacing the Power Cube Module on the Head Interface
Replacing the Power Cube Module on the Head Interface
Overview
Removal
SXDX12V1V2
► Remove the head interface. Also read section "3.4.7 Replacing the Head Interface [03055072-xx]"
[➙92].
► Remove the four screws fastening the power cube and carefully lift off the power cube from the head
interface.
Installation
► Installation is performed by following the above instructions in the reverse order. Also observe the
following instructions:
See also
3.4.7 Replacing the Head Interface [03055072-xx] [ ➙ 92]
NOTICE
C&P20 P
The following additional conditions must be fulfilled for operating a C&P20 P:
► The MODULE / Powercube must have at least function state [03055514-02].
► You find a complete list of the prerequisites in section Replacing the C&P20 P Head.
MODULE / Powercube [03055514-xx]
NOTICE
Installation instructions
► Make sure that the power cube is positioned correctly.

Service Work Conveyor
Gantries 3.4.9 Replacing the Vision Board Spread Spectrum HCU [03067289-xx]
94 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
3.4.9
3.4.9 Replacing the Vision Board Spread Spectrum HCU [03067289-xx]
Replacing the Vision Board Spread Spectrum HCU [03067289-xx]
Parts, Equipment and Tools
▪ Vision Board Spread Spectrum HCU assembly [03067289-xx]
Overview
Removal
Boards on the Gantry
1. Vision board spread spectrum
2. Head adapter (here the version for the TwinHead with
two HCUs)
3. HCU
4. Head interface
5. Sensor module X
► Switch off the machine, disconnect it from the power
supply and secure it to prevent unauthorized reacti-
vation. Observe the instructions in section "1.2 Pre-
paratory Work..." [ ➙ 13].
► If there is a cover above the boards, dismantle it.
► Open the cable clamps (2) on the two PCB camera
cables (4) and disconnect the cables. You may want
to mark their positions, to make clear assignment
easier later on.
► Disconnect the flat ribbon cable (3).
► Remove the cable tie. (5).
► Undo the five screws (1) fastening the Vision board