00196497-07_SM_SXDX12_en.pdf - 第180页

Service Work Conveyor Conveyor 3.6.8 PCBs 180 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 3.6.8 3 . 6 . 8 P C B s PCBs 3.6.8.1 3 . 6 . 8 . 1 R e p la c in g t h e C o n v e y o r C o n t r o l T S P 4 0 0 [ 0 3 0 6 0 8 1…

100%1 / 334
Service Work Conveyor
3.6.7 Stoppers and Sensors Conveyor
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 179
3.6.7.4
3.6.7.4 Replacing the Solenoid Valve (Sensor Rail) [03089866-xx]
Replacing the Solenoid Valve (Sensor Rail) [03089866-xx]
Parts, equipment and tools
Solenoid valve 5/2-micro-way valve 518 [03089866-xx]
Overview
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 13].
Dismantle the sensor rail cover plate over the relevant solenoid valve.
Unplug the solenoid valve from all electrical and pneumatic connections. You may want to mark the
positions of these connections, to make clear assignment easier later on.
Loosen the two screws fastening the solenoid valve.
Installation
Follow the removal instructions in reverse order for installation.
1. Solenoid valve
2. Screws fastening the solenoid valve
3. Compressed air connections
4. Electrical connection
NOTICE!
You do not need to dismantle the sensor rail!
Service Work Conveyor
Conveyor 3.6.8 PCBs
180 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
3.6.8
3.6.8 PCBs
PCBs
3.6.8.1
3.6.8.1 Replacing the Conveyor Control TSP400 [03060811-xx]
Replacing the Conveyor Control TSP400 [03060811-xx]
Parts, equipment and tools
Conveyor control TSP400 assembly [03060811-xx]
Overview
Removal
Use the software to move the conveyor sides into the position which allows you best access. Alter-
natively, you can also loosen the conveyor side clamps on the dual conveyor (see "3.6.1 Loosening
the Conveyor Side Clamps" [ ➙ 143]).
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 13].
Loosen the screw fastening the cover and remove the cover.
Unplug all electrical connections to the conveyor control. Mark their positions, to make clear assign-
ment easier later on.
Loosen the screws fastening the mount and remove the conveyor control from the machine, together
with the bracket.
Loosen the screws fastening the conveyor control to the mount and take the conveyor control off the
mount.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
1. TSP400 (under the cover)
2. Screws fastening the covers (1x each, may not apply
for some machine versions)
For an overview of the connectors, switches etc. of the
TSP400, refer to section "5.3 Conveyor" [ ➙ 321].
One TSP400 is fitted on single conveyors; two are fitted
on dual conveyors.
CAUTION
Installation instructions
If the old conveyor control has an options board, this needs to be refitted on the new con-
veyor control. To do this, unplug all connections for the options board, loosen the fastening
screws and remove the options board.
Check the firmware and perform a download, if needed. (see "4.9.1 Firmware Download
(SW 70x)" [ ➙ 293]).
Service Work Conveyor
3.6.9 Changing Fixed Side Left/Right (EC Only) Conveyor
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 181
3.6.9
3.6.9 Changing Fixed Side Left/Right (EC Only)
Changing Fixed Side Left/Right (EC Only)
Parts, equipment and tools
Setting gauge for ultrasonic sensors [03076989-xx]
Programming cable for PXS240 sensor [03073330-xx]
Dowel pin (supplied with conveyor) [03064582-xx]
Overview
Single conveyor: flexible side left
NOTICE
Minimum conveyor width at conveyor with FS02
After conversion to "fixed side left", the minimum conveyor width on the conveyor with FS02 is
100 mm.
(1) Output side (2) Input side
(3) Side flange 2, fixed (output side) (4) Side flange 1, fixed (input side)
(5) Side flange on the flexible conveyor side
(output side)
(6) Side flange on the flexible conveyor side
(input side)
T Transport direction