Description of the Circuit Boards Electrics and Control 5.1.3 I/O control unit [0 3116049-xx] 304 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 Overview 03052315-0 2 Settings DIP switch block S1 [03052315-02] [03116049-01]…

100%1 / 334
Description of the Circuit Boards
5.1.3 I/O control unit [03116049-xx] Electrics and Control
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 303
5.1.3
5.1.3 I/O control unit [03116049-xx]
I/O control unit [03116049-xx]
Overview
03116049-01
NOTICE
Downwards compatibility
The I/O control unit II [03116049-xx] is downwards compatible with I/O control unit [03052315-
xx].
All connections and designations are identical.
Overview of I/O control unit [03052315-xx]
1. Status LEDs
2. X9qb: Power supply
3. X1qb: CAN bus 1
4. X10qb: Connection of other I/O modules possi-
ble
5. Red LED
This signals a RESET.
6. H1: 7 segment display
(flashing = O.K.)
7. DIP switch S1
8. Outputs X3qb to X8qb
Description of the Circuit Boards
Electrics and Control 5.1.3 I/O control unit [03116049-xx]
304 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
Overview 03052315-02
Settings
DIP switch block S1 [03052315-02] [03116049-01]
Switch Status Description
S1.1 ON/OFF ON: SX4/DX4, X-Series S
OFF: SX1/SX2, DX1/DX2
S1.2 ON/OFF Ballast resistance
ON: SX1/SX2 from machine no.: N001
OFF: SX4/DX4; X-Series S, SX1/SX2 up to machine no.: Mxxx
S1.3 OFF Reserved
S1.4 OFF Reserved
S1.5 OFF Reserved
S1.6 OFF ON: serial bootstrap mode, make sure that S1.7 must be OFF
OFF: Standard mode
S1.7 OFF ON: CAN bootstrap mode, make sure that S1.6 must be OFF
OFF: Standard mode
S1.8 OFF ON: module in the RESET status
OFF: Standard mode
Description of the Circuit Boards
5.1.3 I/O control unit [03116049-xx] Electrics and Control
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 305
LEDs, Displays
03052315-02
7-segment display H1 [03052315-02]
Display Status Description
Dot Flashes Circuit board OK
0 ON Firmware OK
1 ON CAN telegram cannot be transmitted
2 ON FW error: overflow in the CAN bus receiver buffer
3 ON CAN bus controller in the status ERROR PASSIVE
4 ON CAN bus controller in the status BUS OFF
5 ON Processor board received a message instead of a com-
mand
6 ON PowerFail signal active
F ON Other error
Any ON Hardware problem
A ON When initializing: BIOS mode changes to application mode
b ON When booting: head processor remains in BIOS mode