00196497-07_SM_SXDX12_en.pdf - 第89页

Service Work Conveyor 3.4.4 Replacing the Gantry Interface X [030 65078 - xx] Gantries Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 89 Installation Adhesive Tape for Gantry Interface ► Follow the removal in structions in …

100%1 / 334
Service Work Conveyor
Gantries 3.4.4 Replacing the Gantry Interface X [03065078-xx]
88 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
3.4.4
3.4.4 Replacing the Gantry InterfaceX [03065078-xx]
Replacing the Gantry Interface X [03065078-xx]
Parts, equipment and tools
Gantry interface X passive 1 [03065078-xx]
Overview
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 13].
Remove the cover above the gantry interface. Depending on the version this is secured with press
studs or screws.
Loosen the connections on the pneumatic hoses which lead away from the gantry interface.
Unplug the electrical connections of the Y trailing cable on the top side of the gantry interface.
Loosen the four screws fastening the gantry interface.
Unplug the electrical connections on the underside of the gantry interface and remove the interface
from the machine.
1. Gantry interface X (without cover)
2. Pneumatic hoses (without cover)
3. Cover above the gantry interface X
Service Work Conveyor
3.4.4 Replacing the Gantry Interface X [03065078-xx] Gantries
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 89
Installation
Adhesive Tape for Gantry Interface
Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
CAUTION!
During assembly, make sure that the connection rail con-
tacts are insulated with adhesive tape (1) in the direction
of the aluminum holder (2). Do not use conductive tape,
recommendation [03000372-xx] "PTFE glass fiber mate-
rial, self-adhesive, width 20mm" for insulating the con-
tacts.
CAUTION!
During installation, lay the flat ribbon cables of the X trail-
ing cable in a slight S shape to prevent the hoses from
pressing against the flat ribbon cables and the connec-
tors.
1. Bend the flat ribbon cable on the trailing interface into
shape
2. Flat ribbon cable on the trailing interface
Service Work Conveyor
Gantries 3.4.5 Replacing the Gantry Interface Y [03065335-xx]
90 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
3.4.5
3.4.5 Replacing the Gantry InterfaceY [03065335-xx]
Replacing the Gantry Interface Y [03065335-xx]
Parts, equipment and tools
Gantry interface Y [03065335-xx]
Overview
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 13].
Unplug the pneumatic hoses which lead away from the gantry interface.
Remove the covers above the board. Depending on the version the top cover is secured with press
studs or screws.
Unplug the electrical connections on the top of the gantry interface. You may want to mark their po-
sitions, to make clear assignment easier later on.
Loosen the two screws fastening the cover under the gantry interface.
Unplug the electrical connections on the underside of the gantry interface. You may want to mark
their positions, to make clear assignment easier later on.
Loosen the two screws fastening the gantry interface and remove the interface from the machine.
Installation
Follow the removal instructions in reverse order for installation.
1. Gantry interface Y
2. Cover
3. Pneumatic hoses