00196497-07_SM_SXDX12_en.pdf - 第117页

Service Work Conveyor 3.4.21 Replacing the Guide C arriage/Loose Bearing Gantries Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 117 3.4.21 3 . 4 . 2 1 R e p la c in g t h e G u id e C a r r ia g e / L o o s e B e a r in g …

100%1 / 334
Service Work Conveyor
Gantries 3.4.20 Replacing the Head Adapter for the HCU and MHCU/HCU
116 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
If you have ordered the base adapter without HCU(s) you will have to convert the HCU(s).
Remove the two screws fastening the HCU on the underside of the board and carefully pull the HCU
off the base adapter. Make sure not to damage the pins located below. Repeat this procedure for the
second HCU, if necessary (for TwinHead only).
Installation
Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
See also
5.2.5.2 Base adapter TWIN [03055517-xx] [ ➙ 319]
5.2.5.1 Base adapter C&P [03055516-xx] [ ➙ 317]
Head adapter HCU (here the TwinHead version)
Unplug all electrical connections. You may want to
mark their positions, to make clear assignment easier
later on.
Remove the two front screws (1) fastening the HCU
in each case. Make sure that you do not lose the
shims. Make a note of the number of washers used
for each screw, as this may well differ.
Undo all the screws (2) fastening the board and then
remove the board.
CAUTION
Installation instructions
Check the firmware and perform a download, if needed. (See "4.9.1 Firmware Download
(SW 70x)" [ ➙ 293])
Service Work Conveyor
3.4.21 Replacing the Guide Carriage/Loose Bearing Gantries
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 117
3.4.21
3.4.21 Replacing the Guide Carriage/Loose Bearing
Replacing the Guide Carriage/Loose Bearing
Magnets - Danger of Crushing
Guide carriage on the gantry
NOTE: T his task ma y only be performe d by SIPLACE serv ice techni cians.
DANGER
Danger of crushing
The attraction force of the magnets is 400 Nm.
1 Screws fastening the guide carriages 2 Loose bearing Y-axis
3 Loose bearing X-axis
CAUTION
Do not remove the screws
Removing the screws fastening the guide carriages or the loose bearings leads to tensions that
have a negative effect on the working life of loose bearings, guide carriages, and guide rails.
NOTICE
SIPLACE Service
This task may only be performed by SIPLACE service technicians.
Service Work Conveyor
Gantries 3.4.22 Replacing the Y Linear Motor (Primary Part)
118 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
3.4.22
3.4.22 Replacing the Y Linear Motor (Primary Part)
Replacing the Y Linear Motor (Primary Part)
Magnets - Danger of Crushing
NOTE: T his task ma y only be performe d by SIPLACE serv ice techni cians.
See also
1.2 Preparatory Work... [ ➙ 13]
3.4.23
3.4.23 Replacing the X Linear Motor (Primary Part)
Replacing the X Linear Motor (Primary Part)
Magnets - Danger of Crushing
NOTE: T his task ma y only be performe d by SIPLACE serv ice techni cians.
DANGER
Danger of crushing
The attraction force of the magnets is 400 Nm.
NOTICE
SIPLACE Service
This task may only be performed by SIPLACE service technicians.
DANGER
Danger of crushing
The attraction force of the magnets is 400 Nm.
NOTICE
SIPLACE Service
This task may only be performed by SIPLACE service technicians.