Feeder Inspection Unit 2.0−2 DX1OEC−12−000−A0 DX1OEC−12−000−A0 Sentence No. 2. GENERAL DESCRIPTION

Feeder Inspection Unit
2.0−1
2ダミー(Sectionのレベル1)
2.0ダミー(Sectionのレベル2)

Feeder Inspection Unit
2.0−2
DX1OEC−12−000−A0
DX1OEC−12−000−A0
Sentence No.
2. GENERAL DESCRIPTION

2.1 Overview
Feeder Inspection Unit
2.1−1
DX1OEC−12−260−A0
2.1 Overview
DX1OEC−12−260−A0
Sentence No.
2.1.1 Features
• Capable of checking and correcting tape feeders (pneumatic and motorized feeders).
• Wheel position judgment is enabled (to prevent pickup error and mispositioning).
• Images through the camera can be checked on the monitor screen. (Monochrome image is displayed
even on a color monitor since black−and−white signals are used to output image.)
• One−touch field changeover function, which is convenient for checking the double feeder, eliminates
the need for moving the table.
• The clamp reset lever enables the feeder attaching/detaching works to be reduced.
=REMARKS=
Since the view of the camera is 2 mm long by 2.7 mm wide, the position of the components
exceeding the view size cannot be checked at the component pickup position.
Depending on the color/shape of the component, it could be difficult to see the component position
for checking with embossed carrier tape, etc.
2.1.2 Specifications
Applicable tape feeders (Tape Feeder)
• Pneumatic feeders of 8 − 72mm tape width
• Motorized feeders of 12−72mm tape width
• Pneumatic double feeders
=REMARKS=
The wheel position for the pneumatic feeders and motorized feeders of 32 mm paper cannot be
checked. (Only the operation check will be made.)
Dimensions
• Main body: 285 (W) x 535 (L) x 565 (H) mm
• Power box: 350 (W) x 280 (L) x 160.5 (H) mm (Protruding portion not included)
Weight
• Main body: Approx. 19 kg
• Power box: Approx. 7kg
Power supply
• 100 to 240V AC, 0.2kVA
Air supply
• 0.4MPa, 7 L/min (A.N.R); Can be connected with a φ6 tube.
2.1.3 Available Check Items
• Wheel position in tape feed direction and in tape width direction
(The pneumatic feeders and motorized feeders of 32 mm tape width are excluded.)
• Component pickup position
• Feeding check with feeder control signals (judgment of normal, error and time−out).
• Sensor operating check (cylinder forward/reverse limits, select lamp and tape end detection)