BM料架治具使用手册.pdf - 第60页

4.2 T ape Feeder Operation Check Feeder Inspection Unit 4.2−1 DX1OEC−31−250−A0 4.2 T ape Feeder Operation Check DX1OEC−31−250−A0 Sentence No. 4.2.1 Control Panel Layout and Function Here following describes the names and…

100%1 / 100
Feeder Inspection Unit
4.1 Adjusting Wheel Position
4.1−16
DX1OEC−31−240−B0
= MEMO =
4.2 Tape Feeder Operation Check
Feeder Inspection Unit
4.2−1
DX1OEC−31−250−A0
4.2 Tape Feeder Operation Check
DX1OEC−31−250−A0
Sentence No.
4.2.1 Control Panel Layout and Function
Here following describes the names and function of the switches on the control panel.
TAPE STATUS
LED ON
1
CASSETTE TYPE
2OP 2
FEED
TIMES
30
PEEL
SELECT
1
41
FEED
OK
ERROR TIME UP
AUTO FEED PEEL
Applicable
feeder
Pneumatic feeder
(Double feeder included)
Motorized feeder Criteria
Indicator lamps FEED OK Lights up when operation is normally finished after <AUTO>
is pressed.
When feeder
operation finishes
normally, the lamp will
come on.
ERROR Lights up if no feed operation
is executed within the
prescribed time after
“AUTO” is pressed.
Feeder operation
error
TIME UP Lights up if the cylinder
operation is not detected
within the prescribed time
after “AUTO” is pressed.
Feeder operation
error
TAPE Lights up when the tape detection sensor is turned ON.
(Available for the feeders with tape end detection function.)
Used when checking
sensor for proper
operation.
STATUS Lights up when the cylinder is at the forward limit or reverse
limit with the sensor ON.
(Checks the forward and reverse sensors of the cylinder for
proper operation.)
Check the cylinder
position and sensor
status.
Setting switches CASSETTE
TYPE
Usually, set to “1”.
When using a double feeder, set this switch to “2” to activate
the L side and set it to “1” to activate the R side.
FEED
TIMES
Sets the number of times to
feed. (1 to 4)
Set to “1”.
PEEL
SELECT
Usually, set to “0”.
For 32 mm paper tape, set to
“1”.
Set to “0”.
Feeder Inspection Unit
4.2 Tape Feeder Operation Check
4.2−2
DX1OEC−31−250−A0
Applicable
feeder
CriteriaMotorized feeder
Pneumatic feeder
(Double feeder included)
Operation
switches
AUTO Performs feed operation
according to the setting with
FEED and PEEL switches.
Performs feed operation. A series of feed
operation can be
made.
Check the operation
result with the
indicator lamps.
FEED Each time the button is
pushed, the feed cylinder
reciprocates.
Usually set to “OFF”. (Do not
push the switch.)
(Not used) Check the feed
cylinder for proper
operation.
PEEL Each time the button is
pushed, the peel cylinder
reciprocates.
(Used for 32 mm tape feeder
only.)
Usually set to “OFF”. (Do not
push the switch.)
(Not used) Check the peel
cylinder for proper
operation.
LED ON Enables the wiring check of the feeder select lamp. The feeder select
lamp will come on
whenever this switch
is pressed.