BM料架治具使用手册.pdf - 第94页
Feeder Inspection Unit 7.0−1 7 ダミー (Section のレベル 1) 7.0 ダミー (Section のレベル 2)

Feeder Inspection Unit
6.1 Troubleshooting
6.1−2
DX1OEC−90−140−A0
Problem
Check item Remedial action
The feeder does not run. Is power being supplied to the feeder? Eliminate the trouble by
referring to ‘The power does
not turn ON.’ above.
↓ YES
Is air connected to the feeder? Supply air to the feeder.
↓ YES
Is the air valve ON? Turn ON the air valve.
↓ YES
Is the regulator adjusted? Adjust the air pressure.
↓ YES
Is the PNL cable connected to the power
box?
Connect the PNL cable to the
power box.
↓ YES
Are the “FEED” and “PEEL” switches
are ON?
To operate the feeder in AUTO
mode, do not push “FEED”
and “PEEL” switches.
↓ YES
Check if one of the status indicator lamps
detect an error.
Reset the motor−operated
feeder. *1
Or detach the feeder once
from the clamp stand.
↓ YES
The tape end detection lever of the
motorized feeder is in the tape set
position.
To operate the feeder in AUTO
mode, set the lever in the tape
exhaust position.
↓ YES
After setting the feeder to the clamp
stand, the STATUS lamp on the control
box does not light up.
Something is wrong with the
tape feeder.
Contact us.
=REFERENCE=
*1: Refer to the ‘Operation Manual of the Tape Feeder’ for details on the error items and
resetting method for the motorized feeders.

Feeder Inspection Unit
7.0−1
7ダミー(Sectionのレベル1)
7.0ダミー(Sectionのレベル2)

Feeder Inspection Unit
7.0−2
DX1OEC−A1−AA0−B0
DX1OEC−A1−AA0−B0
Sentence No.
7.RECYCLING
This chapter describes precautions on recycling and disassembling the
components used in the Machine.