BM料架治具使用手册.pdf - 第48页

4.1 Adjusting Wheel Position Feeder Inspection Unit 4.1−5 DX1OEC−31−240−B0 Checking the Wheel Position Hole (or V acuum Position Hole) 1. Set the camera view select lever to the R side. 2. Adjust the focus displayed on t…

100%1 / 100
Feeder Inspection Unit
4.1 Adjusting Wheel Position
4.1−4
DX1OEC−31−240−B0
Supplying Air
1. Open the air valve.
2. Check the air pressure.
Use the regulator to adjust the pressure if necessary. (0.4 MPa (4.1 kgf/cm
2
))
=REMARKS=
Depending on models, the supplied pressure may differ. The tape feeders, however, can be
operated as usual.
(1) (3)
(2)
Regulator
Pressure
gauge
Knob
(1) Pull down the knob to
unlock the regulator.
(2) Turn the knob to
adjust the pressure.
(3) Push up the knob
to lock the regulator
in place.
Valve
4.1 Adjusting Wheel Position
Feeder Inspection Unit
4.1−5
DX1OEC−31−240−B0
Checking the Wheel Position Hole (or Vacuum Position Hole)
1. Set the camera view select lever to the R side.
2. Adjust the focus displayed on the monitor using the adjust knob (Z).
3. Using the knobs (X, Y and Z), adjust the camera position so that the wheel position hole or vacuum
position hole may be aligned with the center of the cross hairs, while observing the X/Y graduation
plates and the monitor.
4. Then, tighten the lock knobs (X, Y and Z) to secure the camera.
=HINT=
To ensure measurement accuracy, tighten the lock knobs to secure the camera in position.
8
V
Lock knob (Y)
Lock knob (X)
Graduation
plate (X)
Graduation
plate (Y)
Adjust knob (X)
X slider
Lock
knob (Z)
Adjust
knob (Z)
Z slider
Y slider
Adjust
knob (Y)
Align the edge of the X slider with
the predetermined graduation.
Align the edge of
the Y slider with
the predetermined
graduation.
V
8
12
16
24
32
44
56
72
MOTOR
V
0603W
AIR
W
=HINT=
How to utilize the graduation plate
The marks on the graduation plate is used for rough positioning with respect to the wheel position
hole of the gauge jig.
Align the edge of the X/Y sliders and graduation plate according to the feeder type and width. This
enables you to find the target wheel holes easily.
Then, make fine−adjustment of the camera position for the wheel position hole of the gauge jig.
The tables below show how the positions on the X/Y graduations plates correspond to the feeder
type.
Pickup position
X slider position Y slider position
Motorized feeder
Pickup position
Wheel positions for 8 72 mm
Pneumatic double feeder
(For 0603)
Pneumatic feeder
Pneumatic double feeder
(Other than 0603)
OK
OK: Two marks do not move and appear
to be overlapped.
Camera
view select
lever
Y direction
(Feed direction)
X direction
(Width
direction)
NG: Two marks appear to be misaligned
after switching the lever.
After switching
camera view
select lever
Before switching
camera view
select lever
Feeder Inspection Unit
4.1 Adjusting Wheel Position
4.1−6
DX1OEC−31−240−B0
Checking the Camera Position
1. Attach the gauge jig to the clamp stand.
2. Set the camera view select lever to the R side.
3. Align the gauge hole (V
R
) with the center of the monitor
by adjusting the knobs (X, Y and Z).
=HINT=
The Z adjustment knob is used for camera focusing.
4. Positioning is correct when the gauge hole (V
L
) appears
at the center of the monitor when the camera view select
lever is set to the L side.
5. If the camera position is not correct, re−adjustment is
necessary. (Refer to ‘5.1.1 Adjusting the Camera
Position’.)