AL1_SiplaceX-en.pdf - 第179页

1 - 17 S tudent Guide SIPLACE X Edition 02/2005 5 Collect&Place-Head 20 17 5.1.4.3 Overview V acumm supply 5 Fig. 5.1 - 5 General overview of the function Vacuum e.g . Se gm e nt 1 In ter medi a te bo ard Z-a x is A …

100%1 / 305
1 - 16
Student Guide SIPLACE X
5 Collect&Place-Head 20 Edition 02/2005
16
5.1.4.2 Overview Air kiss supply
Red (light grey): Vacuum
Blue (black): pressure air (Air kiss)
5
Fig. 5.1 - 4 General overview ot the function Air kiss
Position Description Part No.
1 Distributor disc
03008286-0X
Holding
circuit
Intermediate
board
Z-axis
B
B
A
Compressed
air distributor
(4.8-5.0bar)
MC
C
C
A
A
e.g. Segment 1
Pickup/
placement
circuit
Measurement of
vacuum/air kiss values is
performed in the
pressure control valve
CAN bus
1
Retract unit
Z-axis
Cooling system
X-motor
Holding
circuit
Intermediate
board
Z-axis
B
B
A
Compressed
air distributor
(4.8-5.0bar)
MC
C
C
A
A
e.g. Segment 1
Pickup/
placement
circuit
Measurement of
vacuum/air kiss values is
performed in the
pressure control valve
CAN bus
11
Retract unit
Z-axis
Cooling system
X-motor
1 - 17
Student Guide SIPLACE X
Edition 02/2005 5 Collect&Place-Head 20
17
5.1.4.3 Overview Vacumm supply
5
Fig. 5.1 - 5 General overview of the function Vacuum
e.g. Segment 1
Intermediate
board
Z-axis
A
B
C
B
A
A
Compressed air
distributor
(4.8-5.0bar)
MC
CAN bus
C
Cooling system
X-motor
Retract unit
Z-axis
Pickup/
placement
circuit
A
Measurement of vacuum/
air kiss values is
performed in the
pressure control valve
e.g. Segment 1
Intermediate
board
Z-axis
A
B
C
B
A
A
Compressed air
distributor
(4.8-5.0bar)
MC
CAN bus
C
Cooling system
X-motor
Retract unit
Z-axis
Pickup/
placement
circuit
A
Measurement of vacuum/
air kiss values is
performed in the
pressure control valve
1 - 18
Student Guide SIPLACE X
5 Collect&Place-Head 20 Edition 02/2005
18
Note: