AL1_SiplaceX-en.pdf - 第216页
1 - 54 S tudent Guide SIPLACE X 5 Collect&Place-Head 20 Edition 02/2005 54 5.5.4 Control unit for nozzle changer of the C&P heads The nozzle changer are con trolled depend on the configuration of the loca tion at…

1 - 53
Student Guide SIPLACE X
Edition 02/2005 5 Collect&Place-Head 20
53
5.5.3 Assembly with adjusting tool of nozzle changer 20 segment C&P- head
So that the safe distance gets large sufficiently between head and nozzle changer and this one
strained himself isn't exhausted by the machine tolerances, the edition of the nozzle changer, the
so-called docking unit is adjusted to 20 mm +/-0,2mm by means of a teaching to the head. The
adjustment tool will be placed at the position of the pressure control valve. The pressure control
valve has to be unscrewed (not removed). Now it is possible to put on the adjusting tool without
any problems. The support of the nozzle changer carrier has to be adjusted with washers in its
height until the the nominal distance is acchieved and then it has to be fixed.
Fig. 5.5 - 3 Assembly with adjusting tool of nozzle changer at C&P20- head (part no. 03035130-0x)
Please Note for assembling the nozzle changer :
During assembling the nozzle changer keep attention that the component reject box can be easily
removed. Don´t use to long screws, otherwise the component reject box will be fixed.
Please Note for assembling the adjusting tool:
During assembling the adjustment tool keep attention that this will be done between transport and
component table. Otherwise it is not possible to put the head beyond the transport .
20mm +/- 0,2mm

1 - 54
Student Guide SIPLACE X
5 Collect&Place-Head 20 Edition 02/2005
54
5.5.4 Control unit for nozzle changer of the C&P heads
The nozzle changer are controlled depend on the configuration of the location at the machine via
CAN Bus (SLIO Main- und Sub-Distributor). In future with the SW 505 the nozzle changer are con-
trolled via the "One Wire Bus". Soleniods control the pneumatic rotary drives and open or close
the nozzle changer..
Legende
5.5.5 Pneumatic plan for nozzle changer
Fig. 5.5 - 4 Pressure air supply for the nozzle changer
The air pressure supply of the nozzle changer will be assembled by the T-piece as shown in the
picture below. A additional Y- piece is necessary for the optional 2
nd
Nozzle changer carrier.
(1) SUB-D connector machine CAN Bus (2) SUB-D connector Option ( reject boxes / 24 V)
(3) ribbon cable nozzle changer 1 (4) ribbon cable nozzle changer 2
3
area-
coding
LED check
noz.ch. 2
12
34
LED check DLM
noz.ch. 1
3
4
2
1
Gantry 1 - 4
4
3
2
1
Bulkcase
Feeder
COT 1-4
2,5 bar
adjustable
Nozzle
changer
1 2
34
Nozzle changer
Gantry 1 - 4
2,5 bar
adjustable
Docking unit
1 - 4
5 bar
adjustable
Conveyor
5 bar
adjustable
5 bar
adjustable
1 2 3 4
Compressed air distributor block
Tape cutter
1 - 4
4 3
21
+
nozzle changer
C&P20
(4,5bar)

1 - 55
Student Guide SIPLACE X
Edition 02/2005 5 Collect&Place-Head 20
55
Fig. 5.5 - 5 Air pressure connection of the nozzle changer
The DLM nozzle changers are connected to 2.5 bar (loopedhose in the picture). The C&P20 noz-
zelchanger is connected to 4.5 bar.
CAN- Bus connector of nozzle
changer
Air pressure connection of nozzle changer