1 - 19 S tudent Guide SIPLACE X Edition 02/2005 6 T win-Head 19 6.4 Adjustment s 6.4.1 Description of the boards on the T win- Head All described adjustment s in this chapter are head specific and are necessary here for …

1 - 19
Student Guide SIPLACE X
Edition 02/2005 6 Twin-Head
19
6.4 Adjustments
6.4.1 Description of the boards on the Twin- Head
All described adjustments in this chapter are head specific and are necessary here for the
Twin Head.
6.4.1.1 Head adapter Twin- Head
The head adapter board connects the head interface from the bottom side directly.The main board
of Twin head segment 1 and 2 is connected via ribbon cable to the adapter board. This head
adapter must be changed for head modularity, if you use a C&P head.
Fig. 6.4 - 1 Head adapter Twin head
Please Note: The ribbon cable sets for the Twin head segment 1and 2 are different.
(1) Connector Z-Axis Twin head 1 (2) Connector D-Axis Twin head 1
(3) Connector DP-Axis Twin head 2 (4) Connector Z-Axis Twin head 2
(5) DIP Switch (without function) (6) LED C167 = ON TQM Module on the head
interface C500 --> OK
(to 5) PP1 Boot CAN Processor Twin Segm. 1 (to 5) PP1 Reset CAN Processor Twin Segm. 1
(to 5) PP2 Boot CAN Processor Twin Segm. 2 (to 5) PP2 Reset CAN Processor Twin Segm. 2
1
24
3
5
C167
6

1 - 20
Student Guide SIPLACE X
6 Twin-Head Edition 02/2005
20
6.4.1.2 Twin- Head main board
The main board is mounted directly on the top of the frame of the TWIN-head. This board is con-
nected to the head adapter via two ribbon cable (one ribbon cable for each axis). The difference
to the Twin Head on the HF machine is now, that we don‘t use the 16 Bit Can Prozessor on each
main board. The control of both Twin heads will make the Can Prozessor on the head interface
C500.
Fig. 6.4 - 2 Main board at TWIN-head (00352833-xx)
1. Connector for the 16 Bit CAN Bus Processor (Control the analog or digital vacuumgenerator)
2. LED´S signs (Description from top to bottom/ on the board in German language)
– D8 without function (retract unit)
– D7 KLEMM: (retract unit)
– D6 BERO: Z-axis top (not used)
– D1 DRUCK: at the moment not used/ Z-Druck (Z-Pressure)
– D2 KLEMM: Clamping Z-axis (yellow) LED off, retract unit is at top position
2
3
4
5
8
6
9
10
11
12
X21
X8
7
1