EUKYX-199-4110_G5S2_Instruction_Vol4_E.pdf - 第100页
EUKYX 1-51 199-4100 4.8 X/Y Beam Section X-Axis Cable Fixing Places (2 locations) Every 6 Months Inspection Required T ime: 1 minute Check visually for any abnormality such as cracks. X-Axis Cable Side Faces Every 6 Mont…

EUKYX
1-50199-4100
4.8 X/Y Beam Section
Y-Axis Linear Guides (2 locations)
Every Day Inspection
Required Time: 1 minute
Check visually for any dropped foreign object,
etc.
Y-Axis Linear Guides (8 locations)
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
Wipe off old grease with a rag and apply new
grease to the grease nipples with a hand grease
gun.
Take ample care not to leave
any waste threads after cleaning.
Grease should be applied every 3 months after
the initial month.
Notice
F4A34A

EUKYX
1-51199-4100
4.8 X/Y Beam Section
X-Axis Cable Fixing Places (2 locations)
Every 6 Months Inspection
Required Time: 1 minute
Check visually for any abnormality such as
cracks.
X-Axis Cable Side Faces
Every 6 Months Cleaning and Lubrication
(BARRIERTA IEL/V)
Required Time: 3 minutes
(1)
Wipe off old grease with a rag for wiping oil.
(2) Apply new grease by hand or with a brush.
Take ample care not to leave
any waste threads after
cleaning.
Notice
X-Axis Linear Scale
Every 6 Months Cleaning
Required Time: 5 minutes
When it is very dirty, clean it using a rag soaked
in alcohol.
F4A35A

EUKYX
1-52199-4100
4.8 X/Y Beam Section
Y-Axis Cable Fixing Places (2 locations)
Every 6 Months Inspection
Required Time: 1 minute
Check visually for any abnormality such as
cracks.
Y-Axis Linear Scale
Every 6 Months Cleaning
Required Time: 5 minutes
When it is very dirty, clean it using a rag
soaked in alcohol.
Y-Axis Cable Side Faces
Every 6 Months Cleaning and Lubrication
(BARRIERTA IEL/V)
Required Time: 3 minutes
(1)
Wipe off old grease with a rag for wiping oil.
(2) Apply new grease by hand or with a brush.
Take ample care not to leave
any waste threads after
cleaning.
Notice
F4A39A