EUKYX-199-4110_G5S2_Instruction_Vol4_E.pdf - 第135页

EUKYX 2-6 199-4100 2.2 Management Information list Code D isp lay Ar ea A Di spl ay Are a B 1310 8 Feede r set Err The re is a fee der w hic h is not ex tra cte d fro m mach ine af ter t ape setting error det ection. Ple…

100%1 / 363
EUKYX
2-5199-4100
2.2 Management Information list
Code Display Area A Display Area B
11c 02
Nozzle arrangement
confirmation
A nozzle cannot be stored. Please check the following. (Block 1)
1. Existence of Nozzle Stocker, Clamp Condition
2. Nozzle Configuration Data
11c 03
Nozzle arrangement
confirmation
A nozzle cannot be stored. Please check the following. (Block 2)
1. Existence of Nozzle Stocker, Clamp Condition
2. Nozzle Configuration Data
11c 04
Nozzle arrangement
confirmation
The nozzles to be used are insufficient. Please check the following.
(Block 1)
1. Existence of Nozzle Stocker, Clamp Condition
2. Nozzle Configuration Data
11c 05
Nozzle arrangement
confirmation
The nozzles to be used are insufficient. Please check the following.
(Block 2)
1. Existence of Nozzle Stocker, Clamp Condition
2. Nozzle Configuration Data
11c 0 6
Nozzle arrangement
confirmation
The nozzle placement of the head to assist for is different. (Head2)
11c 07
Nozzle arrangement
confirmation
The nozzle placement of the head to assist for is different. (Head1)
11c 08
Nozzle arrangement
confirmation
The Nozzle used is insufficient for assist. Please arrange the Nozzle
used.
11c 09
Nozzle arrangement
confirmation
Nozzle placement of Nozzle Stocker is short, the sequence that cannot
change a nozzle for exists. Please confirm nozzle stocker placement.
11c 0a
Nozzle arrangement
confirmation
A nozzle exists on Nozzle Stocker, but the sequence that cannot
change a nozzle for by the limitation of the head exists. Please confirm
nozzle stocker placement.
12a01
Tray shortage Comp
(Block1)
Please supply Tray Cmpnt, close Tray Safety door and push Tray
Ready SW (Block1).
12a02
Tray shortage Comp
(Block1)
There is the shortage components. Please supply the components.
12b01
Tray shortage Comp
(Block2)
Please supply Tray Cmpnt, close Tray Safety door and push Tray
Ready SW (Block2).
12b02
Tray shortage Comp
(Block2)
There is the shortage components. Please supply the components.
12c01
Tray is not ready
(Block1)
Error signal of the unit is detected.\r\n(1) Please supply the
components. (2) Please close elevator loading door.\r\n(3) Please
press a reset button. (4) Please release Inhibit button.
12d01
Tray is not ready
(Block2)
Error signal of the unit is detected.\r\n(1) Please supply the
components. (2) Please close elevator loading door.\r\n(3) Please
press a reset button. (4) Please release Inhibit button.
13101 Feeder set Err
A pickup miss comp is detected. (Block1) Please open the safety door
and confirm whether pickup miss comp is dropped. If the comp is
dropped, there is a possibility of interference with Head. A detection
state can be checked on a control screen.
13102 Feeder set Err
The feeder latch worked off. (Block1)
Please close the hook of a feeder. A detection state can be checked
on a control screen.
13103 Feeder set Err
A pickup miss comp is detected. (Block2) Please open the safety door
and confirm whether pickup miss comp is dropped. If the comp is
dropped, there is a possibility of interference with Head. A detection
state can be checked on a control screen.
13104 Feeder set Err
Feeder Latch worked off. (Block2)
Please close the hook of a feeder. A detection state can be checked
on a control screen.
13105 Feeder set Err Not connect selected Feeder.
EUKYX
2-6199-4100
2.2 Management Information list
Code Display Area A Display Area B
13108 Feeder set Err
There is a feeder which is not extracted from machine after tape
setting error detection.
Please extract a feeder from machine once and set a tape to a joint
detecting sensor correctly.
13b01 Stage Ready SW Please wait Stage Ready on.
13c01 Feeder Ready SW Please wait Feeder Ready on
13c02 Feeder Ready SW Do not open Safety Cover while side view camera program is updating.
14101 Operation Parameter
Test mode of transfer set "Disable" in pass mode.
Check settings.
14102 Operation Parameter
Operation Mode both Lane A, B is [STOP]. Please execute after reset
it.
14103 Operation Parameter
Operation Mode is set except [Placement]. Please set [Placement
when do 1 Cmpnt placement.
14201 Device System Setup Please set Input Machine Output Mode [SMEMA Mode].
14202 Device System Setup Please set Output Machine Output Mode [SMEMA Mode].
14b01
Nozzle Placement Data
Check
Current Program Data differs from Nozzle Arrangement Data of Nozzle
Stocker.
15001 Nozzle Location Check
Not found fitting nozzle for Teaching (Head1). Set type "HA09" nozzle
as Nozzle1 on Head.
15002 Nozzle Location Check
Not found fitting nozzle for Teaching (Head2). Set type "HA09" nozzle
as Nozzle1 on Head.
15003 Nozzle Location Check
Not found fitting nozzle for Teaching (Head1). Set type "HA09"nozzle
on Head.
15004 Nozzle Location Check
Not found fitting nozzle for Teaching (Head2).Set type "HA09"nozzle
on Head.
15005 Nozzle Location Check
Not found fitting nozzle for Teaching (Head1). Set type "FF01"or "FF02"
nozzle on Head.
15006 Nozzle Location Check
Not found fitting nozzle for Teaching (Head2). Set type "FF01"or
"FF02" nozzle on Head.
15007 Nozzle Location Check The different type nozzle is already set (Head1). Please remove it.
15008 Nozzle Location Check The different type nozzle is already set (Head2). Please remove it.
15009 Nozzle Location Check
Not found fitting nozzle for Teaching (Head1).
Set type "FF01"or "FF02" nozzle as Nozzle2 on Head.
1500A Nozzle Location Check
Not found fitting nozzle for Teaching (Head2).
Set type "FF01"or "FF02" nozzle as Nozzle2 on Head.
1500B Nozzle Location Check
Not found fitting nozzle for Teaching (Head1).
Set type "VF02" nozzle on calibrate position.
1500C Nozzle Location Check
Not found fitting nozzle for Teaching (Head2). Set type "VF02" nozzle
on Head.
1500D Nozzle Location Check
Not found fitting nozzle for Teaching (Head1). Set type "HA09"or
"VF02" nozzle on Head.
1500E Nozzle Location Check
Not found fitting nozzle for Teaching (Head2). Set type "HA09"or
"VF02" nozzle on Head.
1500F Nozzle Location Check
Not found fitting nozzle for Teaching (Head1). Please set type "HA09"
nozzle in the stocker position where nozzle can change.
15010 Nozzle Location Check
Not found fitting nozzle for Teaching (Head2). Please set type "HA09"
nozzle in the stocker position where nozzle can change.
15011 Nozzle Location Check
Not found fitting nozzle for Teaching (Head1). Please set type "FF01"
or "FF02" nozzle in the stocker position where nozzle can change.
15012 Nozzle Location Check
Not found fitting nozzle for Teaching (Head2). Please set type "FF01"
or "FF02" nozzle in the stocker position where nozzle can change.
EUKYX
2-7199-4100
2.2 Management Information list
Code Display Area A Display Area B
15013 Nozzle Location Check
Not found fitting nozzle for Teaching (Head1). Please set type "BF02"
nozzle in the stocker position where nozzle can change.
15014 Nozzle Location Check
Not found fitting nozzle for Teaching (Head2). Please set type "BF02"
nozzle in the stocker position where nozzle can change.
15015 Nozzle Location Check
Not found fitting nozzle for Teaching (Head1). Please set type "FA04"
nozzle in the stocker position where nozzle can change.
15016 Nozzle Location Check
Not found fitting nozzle for Teaching (Head2). Please set type "FA04"
nozzle in the stocker position where nozzle can change.
15017 Nozzle Location Check
Not found fitting nozzle for Teaching (Head1). Please set type "BF02"
or "HA09" nozzle in the stocker position where nozzle can change.
15018 Nozzle Location Check
Not found fitting nozzle for Teaching (Head2). Please set type "BF02"
or "HA09" nozzle in the stocker position where nozzle can change.
15019 Nozzle Location Check
Not found fitting nozzle for Teaching (Head1).
Set type "HA09" or "HV19" nozzle as Nozzle1 on Head.
1501A Nozzle Location Check
Not found fitting nozzle for Teaching (Head2).
Set type "HA09" or "HV19" nozzle as Nozzle1 on Head.
1501B Nozzle Location Check
Not found fitting nozzle for Teaching (Head1). Please set type "HA09"
or "HV19" nozzle in the stocker position where nozzle can change.
1501C Nozzle Location Check
Not found fitting nozzle for Teaching (Head2). Please set type "HA09"
or "HV19" nozzle in the stocker position where nozzle can change.
1501D Nozzle Location Check
Not found fitting nozzle for Teaching (Head1). Please set type "BF02"
or "HA09" or "HV19" nozzle in the stocker position where nozzle can
change.
1501E Nozzle Location Check
Not found fitting nozzle for Teaching (Head2). Please set type "BF02"
or "HA09" or "HV19" nozzle in the stocker position where nozzle can
change.
1501F Nozzle Location Check
Not found fitting nozzle for Teaching (Head1). Please set type "PM01"
nozzle in the stocker position where nozzle can change.
15020 Nozzle Location Check
Not found fitting nozzle for Teaching (Head2). Please set type "PM01"
nozzle in the stocker position where nozzle can change.
15101
Nozzle location
teaching, check the
position of nozzle on
head
No found nozzle (Head1). Or, the different Nozzle could be arranged.
15102
Nozzle location
teaching, check on the
position of nozzle on
head
No found nozzle (Head2). Or, the different Nozzle could be arranged.
15201
Teaching check the
conveyor
No PCB on Conveyor. Please put PCB in.
15202
Teaching check the
conveyor
Please set PCB positioning. Please set it again after cancel positioning
if PCB positioning is already done.
15203
Teaching check the
conveyor
Please push Conveyor Width Moving.
15301
ODD Head Nozzle
stocker check
There does not exist stocker that can replace nozzle (Block1).
15302
ODD Head Nozzle
stocker check
There does not exist stocker that can replace nozzle (Block2).
16001 Tray teaching Traverse of Tray is not drawn out (Block1). Draw out Traverse.
16002 Tray teaching Tray Traverse is not drawn out (Block2). Draw out Traverse.
16003 Tray teaching
The component of the specified number of matrices cannot be photoed
with a PEC recognition camera.
16004 Tray teaching The component is not drawn out (Block1). Draw out the component.