EUKYX
1-63199-4100
5.1 Vacuum Nozzle Cleaning procedure
5.1 Vacuum Nozzle Cleaning procedure
Remove Nozzle Filter
Refer to "5.3 Nozzle Filter Removal Procedure"
in this chapter for details.
Blow air to Vacuum Nozzle
Confirm that there is no clog in pick-up hole
Refer to "5.4 Method of Blow air" in this chapter
for details.
Confirm the clog in the top of pick-up hole by
the magnifying glass.
Refer to "5.5 Cleaning of high-speed nozzle
hole part with pin gauge" in this chapter for details.
Remove Vacuum Nozzle
Refer to "5.2 Method of detaching vacuum
nozzle" in this chapter for details.
Insert the nozzle filter
Refer to "5.7 Nozzle Filter Insertion Procedure"
in this chapter for details.
Reference
Reference
Reference
Reference
Reference
F4A47
NOTICE
In the case that the ultra-sonic cleaning and solvent
are used for the nozzle cleaning, the adhesive
applied onto the nozzle joint section would be
degraded, which could cause adhesive ablation and
damage to the nozzle unit.

EUKYX
1-64199-4100
5.2 Method of detaching vacuum nozzles
5.2 Method of detaching vacuum nozzles
• Store the nozzles in the nozzle stocker (housing) through window navigations and take out the
nozzle stocker (housing).
(a) Do not take out a nozzle from the head by hand. Otherwise, the nozzle does not
conform to the nozzle data.
(b) Do not blow air to the vacuum nozzle attached to the head.
The filter may fly out and the head may be damaged.
(c) Demagnetize the vacuum nozzle after the detachment.
Keep the head section free of any magnetic field.
As an example,
• Do not bring a magnet close to the head section.
• Do not bring any demagnetizer to the head section.
Demagnetize the vacuum nozzle each unit.
Refer to “5. “NOZ.CHG.” Window” in "Chapter 6 (Vol. 2)" for the procedure of nozzle
storage.
5.3 Nozzle Filter Removal Procedure
Push out the nozzle filter using the filter removal jig as shown in the following figure.
Filter Removing Jig
Vacuum Nozzle
Push
Pushing out the nozzle filter.
F4A48
Do not re-use the removed nozzle filter.
Notice
Reference
Note

EUKYX
1-65199-4100
5.4 Method of Blow air
5.4 Method of Blow air
• Remove dust and dirt etc.
Remove slight dust and dirt by blowing air or wiping off.
Clean the tapered area of the vacuum nozzle with a lens cleaning cloth.
Use clean, dry, and non-lubricated air for blowing air.
F4A49
NOTICE
When blowing air to the nozzle, make sure to blow
from the nozzle end section.
If blowing air from the clamp claw section, the clamp
claw might be damaged.
Notice