EUKYX-199-4110_G5S2_Instruction_Vol4_E.pdf - 第248页

EUKYX 3-83 199-4100 3.8 Automatic Adjustment Error ID Error Name, Description, Cause, and Remed y 49 076 F N ozzl e set up Erro r in turn ing on PCB r ec og ca mera L igh t ----- 49 07 70 N ozzle s et up Erro r in turn i…

100%1 / 363
EUKYX
3-82199-4100
3.8 Automatic Adjustment
Error ID Error Name, Description, Cause, and Remedy
490760 Nozzle set up
Failed in Z-axis start-up
-----
490761 Nozzle set up
XY-axis Operating has not been completed within predetermined time
-----
490762 Nozzle set up
Error in XY-axis operating
-----
490763 Nozzle set up
XY Beam Operating has not been completed within predetermined time
-----
490764 Nozzle set up
Error in setting Drive Wave of HL-axis
-----
490765 Nozzle set up
Error in setting Drive Wave of NL-axis
-----
490766 Nozzle set up
Error in setting Drive Wave of NL-axis
-----
490767 Nozzle set up
Error in setting Drive Wave of L-axis
-----
490768 Nozzle set up
Up/Down axis start-up has not been completed within predetermined time
-----
490769 Nozzle set up
Failed in HL-axis start-up
-----
49076A Nozzle set up
Failed in NL-axis start-up
-----
49076B Nozzle set up
Failed in L-axis start-up
-----
49076C Nozzle set up
Up/Down axis start-up has not been completed within predetermined time
-----
49076D Nozzle set up
Error in turning on PCB recog camera Light
-----
49076E Nozzle set up
Turning on PCB recog camera Light has not finished within predetermined time
-----
EUKYX
3-83199-4100
3.8 Automatic Adjustment
Error ID Error Name, Description, Cause, and Remedy
49076F Nozzle set up
Error in turning on PCB recog camera Light
-----
490770 Nozzle set up
Error in turning on PCB recog camera Light (Teaching Noz Stocker)
-----
490771 Nozzle set up
Turning on PCB recog camera Light has not finished within predetermined time (Teaching
Noz Stocker)
-----
490772 Nozzle set up
Error in turning on PCB recog camera Light (Teaching Noz Stocker)
-----
490773 Nozzle set up
Error in turning on PCB recog camera Light (Noz Recog)
-----
490774 Nozzle set up
Turning on PCB recog camera Light has not finished within predetermined time (Noz Recog)
-----
490775 Nozzle set up
Error in turning on PCB recog camera Light (Noz Recog)
-----
490776 Nozzle set up
Error in turning off PCB recog camera Light
-----
490777 Nozzle set up
Turning off PCB recog camera Light has not finished within predetermined time
-----
490778 Nozzle set up
Error in turning off PCB recog camera Light
-----
490779 Nozzle set up
Error in capturing a image of PCB recog camera.
-----
49077A Nozzle set up
Capturing a image of PCB recog camera has not finished within predetermined time
-----
49077B Nozzle set up
Error in capturing a image of PCB recog camera.
-----
49077C Nozzle set up
Error in recognizing Noz Stocker Mark
-----
49077D Nozzle set up
Recognizing Noz Stocker Mark has not finished within predetermined time.
-----
EUKYX
3-84199-4100
3.8 Automatic Adjustment
Error ID Error Name, Description, Cause, and Remedy
49077E Nozzle set up
Error in recognizing Noz Stocker Mark
-----
49077F Nozzle set up
Error in recognization of the existence of Noz
-----
490780 Nozzle set up
Recognization of the existence of Noz has not finished within predetermined time
-----
490781 Nozzle set up
Error in recognizing the existence of Noz
-----
490782 Nozzle set up
Error in recognizing Noz ID
-----
490783 Nozzle set up
Recognizing Noz ID has not finished within predetermined time
-----
490784 Nozzle set up
Error in recognizing of Noz ID
-----
490785 Nozzle set up
Time-out of starting Side View Camera detect
-----
490786 Nozzle set up
Time-out of reading out the result of Side View Camera detect
-----
490787 Nozzle set up
Error in the result of Side View Camera detect
-----
490788 Nozzle set up
Time-out of starting Side View Camera detect (Noz diameter Recog)
-----
490789 Nozzle set up
Time-out of reading out the result of Side View Camera detect (Noz diameter Recog)
-----
49078A Nozzle set up
Error in the result of Side View Camera detect (Noz diameter Recog)
-----
49078B Nozzle set up
Failed in getting Noz type Data.
-----
49078C Nozzle set up
Exchanging Noz has not started within predetermined time
-----