EUKYX-199-4110_G5S2_Instruction_Vol4_E.pdf - 第277页
EUKYX 3-1 12 199-4100 3.10 Others Error ID Error Name, Description, Cause, and Remedy 4 b 2 41 3 Feeder (M ov ement Error ) Cann ot sen d T a pe b eca use al arm is f ound i n one sid e La ne of Dual Fe ed er . Plea se e…

EUKYX
3-111199-4100
3.10 Others
Error ID Error Name, Description, Cause, and Remedy
4b2401 Feeder (Movement Error)
Alarm Code:E0 - (1) Damaged cover tape/ (2) Cover tape jammed in the storage/ (3)
Splicing section peeling off
(1) Confirm whether or not the cover tape is set correctly
(2) Please remove the cover tape from the storage section.
(3) Please check the splicing condition if the work performed correctly in the process.
4b2402 Feeder (Movement Error)
Alarm Code:E1 - Cover tape peeling off error (Get caught up)
(1) Confirm whether or not the cover tape is set correctly.
(2) Confirm whether or not some sticky material has adhered to the suppressor.
(3) Confirm the splicing condition if the work performed correctly in the process.
4b2403 Feeder (Movement Error)
Alarm Code:E2 - Origin Position Checking Error (Excessively out of the origin during servo
ON)
If the error occurs frequently, replace the feeder. (It may be caused by trouble of the control
P.C . B . .)
4b2405 Feeder (Movement Error)
Alarm Code:E4 - Positioning Completion Timeout (Foreign substances in the sprocket
wheel)
Confirm whether or not the tape is being jammed on the path.
Confirm the reel to operate smoothly.
Confirm whether or not some components and dust are being caught in the sprocket.
4b2407 Feeder (Movement Error)
Alarm Code:E6 - Lane Change Timeout Error
If the error occurs frequently, replace the feeder. (It may be caused by trouble of the control
P.C . B . .)
4b2408 Feeder (Movement Error)
Alarm Code:E7 - Servo ON Timeout
If the error occurs frequently, replace the feeder.
(It may be caused by trouble of the control P.C.B..)
4b2410 Feeder (Movement Error)
A pickup error occurred due to feeder operation problem.
Please check the feeder and the component.
-----
4b 2411 Feeder (Movement Error)
Alarm Code:E5 - Redundant Order Error (A feeding error may occur.)
Confirm whether or not the tape is being jammed on the path.
Confirm the reel to operate smoothly.
Confirm whether or not some components and dust are being caught in the sprocket.
Confirm whether or not some components and dust are being caught in the tape feeding
gear.
4b2412 Feeder (Movement Error)
Error in confirming connection of Feeder
Please check connection of Feeder

EUKYX
3-112199-4100
3.10 Others
Error ID Error Name, Description, Cause, and Remedy
4b2413 Feeder (Movement Error)
Cannot send Tape because alarm is found in one side Lane of Dual Feeder.
Please execute recovery process, and then operate it again.
4b24a3 Feeder (Movement Error)
Feeder error (feeding time-out)
-----
4b2501 Splicing Operation failed
Alarm Code:E3 - (1)No supplied history/ (2)Dirty splicing detection sensor (dust adhesion)
(1) Please operate to resupply components in the machine after splicing operation.
(2) Please clean the joint detection sensor.
4b2601 Unit P.C.B. B.B.R. Information
There is no information in the relevant P.C.B. (on the Transfer Conveyor).
Delete the BBR information after removing the P.C.B..
4b2602 Unit P.C.B. B.B.R. Information
There is no information in the relevant P.C.B. (on the Transfer XY-Table).
Delete the BBR information after removing the P.C.B..
4b2603 Unit P.C.B. B.B.R. Information
A problem was found in the unit PCB BBR information.
Delete the BBR information after removing the P.C.B..
4b2701 Start Process(Feeder Connection Error)
A special feeder is appointed. Please confirm the model of a set feeder.
-----
4b 2711 Start Process(Feeder Connection Error)
ACV Check Error. Component ID on the feeder is not same as one specified by current
program.
Please check a state on a "Comp.Reload-ACV Check" screen.
4b2713 Start Process(Feeder Connection Error)
There is a splicing failure feeder.
-----
4b2722 Start Process(Feeder Connection Error)
Feeder is not ready
-----
4b02803 PCB-ID communication Error.
A problem was found in the unit PCB ID information.
Delete the P.C.B.-ID information after removing the P.C.B.
4b2c01 Error in connection between CPU
Failed in communications with the Control CPU.
-----
4b2c02 Error in connection between CPU
Failed in communications with the Recog. CPU.
-----
4b3001 Cutter Error
Program Error(There is a operation mode which is not set)
-----

EUKYX
3-113199-4100
3.10 Others
Error ID Error Name, Description, Cause, and Remedy
4b3002 Cutter Error
Cutter open error.
(1) Please confirm whether there is not the becoming shorter of chips.
(2) To a cutter open detection sensor trouble please confirm whether is clean.
(3) Please confirm whether there is not the trouble of the air valve.
(4) Please confirm whether there is not the trouble of the cylinder.
4b3003 Cutter Error
There is a time-out in Cutter-axis.(Zeroing operation start)
-----
4b3004 Cutter Error
Cutter-axis Time-out(Zeroing)
-----
4b3005 Cutter Error
Zeroing of Cutter-axis is not completed.
-----
4b3006 Cutter Error
There is a problem in Cutter-axis. (Positioning Operation)
-----
4b3007 Cutter Error
Cutter-axis Time-out(Positioning Operation)
-----
4b3008 Cutter Error
Alarm of Cutter-axis was detected.
-----
4b3009 Cutter Error
Recede operation was executed because alarm was detected during positioning operation
of Cutter-axis.
Please confirm whether there is an error in cutter unit(Being jammed in cutter layer)
4b300a Cutter Error
Can not communicate with SV-NET P.C.B.
Please confirm AE-LINK wiring and Power wiring.
4b300b Cutter Error
Can not communicate with Driver
Please confirm Power wiring and AE-LINK wiring of driver in Cutter unit.
4b300c Cutter Error
Time-out of waiting for initializing completely
Please confirm AE-LINK wiring and Power wiring.
4b300d Cutter Error
Test mode of cutter is valid.
Please clear the check of [Cutter Movement disable] in the screen of test mode.
4b300e Cutter Error
The set of operation mode of Cutter is Disable.
Please set operating mode of Cutter Enable.
4b300f Cutter Error
Cutter can not move because Feeder Base is in downward position.
Please press READY switch of Feeder Base and move Feeder base to input position.