EUKYX 1-32 199-4100 4.6 Cutter Section 4.6.2 Cut ter Unit Lubrication C yc le : Ever y 3 Mo nths (Required Time : 40 minutes) Grease: D A PHNE GRE ASE MP No. 1 CAUTION After making sure that the power supply has been sto…

100%1 / 363
EUKYX
1-31199-4100
4.6 Cutter Section
(5) Remove dirt and dust in the cutter unit with a vacuum cleaner.
Use a vacuum cleaner nozzle for narrow spaces
.
Shape of recommended
vacuum cleaner nozzle
F4A28
Cutter blade (bottom surface)
Cutter blade
(top surface)
F4A27E
Note
EUKYX
1-32199-4100
4.6 Cutter Section
4.6.2 Cutter Unit Lubrication
Cycle: Every 3 Months (Required Time : 40 minutes)
Grease: DAPHNE GREASE MP No. 1
CAUTION
After making sure that the power supply has been stopped,
start maintenance. During maintenance, do not touch the
cutter blade.
(1) Remove the truss head screws (1 each on left and right) mounting the lower slope. Loosen
the truss head screws at the bottom (1 each on left and right). Detach the lower slope.
Cutter unit
Upper slope
Lower slope
Truss head screw (front side)
Truss head screw (Bottom side)
F4A27AA
(2) Remove hex socket head cap screws mounting the cutter unit (1 each on left and right).
Hex socket head cap screw
F4A27B
Procedure
EUKYX
1-33199-4100
4.6 Cutter Section
(3) Pull out the cutter unit main body forward. Remove 3 unit connection connectors. At this
point, make sure not to tear off the connector cable by pulling them forcibly. Additionally,
take care that the connector cable is not trapped when returning the unit to the original
position.
Connection connectors (3 pcs)
Connector
cable
Front
Cutter unit main body
F4A27C
(4) Pull out the cutter unit main body forward more. Move it over the unit stopper bolts and
detach it from the machine. Make sure to grip the handles firmly in order not to drop the
cutter unit as it is heavy.
Handle
Handle
Unit stopper
bolt
Unit stopper
bolt
Front
F4A27F