EUKYX-199-4110_G5S2_Instruction_Vol4_E.pdf - 第299页

EUKYX 3-134 199-4100 3.13 Auto T eaching Error ID Error Name, Description, Cause, and Remedy 600509 Reference m ark position t each Erro r of the move ment o f Jig st ore of CTR Fly Re co gnit ion ----- 60050a Reference …

100%1 / 363
EUKYX
3-133199-4100
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
600410 Head Rotate center offset teach
Error when L-axis began zeroing
-----
60 0 411 Head Rotate center offset teach
Error while L-axis is on zeroing
-----
600412 Head Rotate center offset teach
Error when Z-axis began to rotate
-----
600413 Head Rotate center offset teach
Error while Z-axis is rotating
-----
600414 Head Rotate center offset teach
Error when L-axis began to drop
-----
600415 Head Rotate center offset teach
Error when L-axis is dropping
-----
600416 Head Rotate center offset teach
Error in Teaching Head Rotate center offset.
-----
600501 Reference mark position teach
Could not recognize Glass Jig in CTR Fly Recognition.
Please confirm that Glass Jig is set on Glass Jig place.(Check it because there is a
possibility that nozzle is not on head, or vacuum is not "ON".)
600502 Reference mark position teach
Error of Recognition Command response in case of CTR Fly Recognition
-----
600503 Reference mark position teach
Could not recognize Standard Mark
1.Please clean a mark part.
2.Please check whether lighting is on.
600504 Reference mark position teach
Error of Recognition Command response in case of Standard Mark Recognition
-----
600505 Reference mark position teach
Error of coordinates calculation of CTR Fly Recognition
-----
600506 Reference mark position teach
Error when Jig pickup of CTR Fly Recognition began
-----
600507 Reference mark position teach
Error of the movement of Jig pickup of CTP Fly Recognition
-----
600508 Reference mark position teach
Error when Jig store of CTR Fly Recognition began
-----
EUKYX
3-134199-4100
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
600509 Reference mark position teach
Error of the movement of Jig store of CTR Fly Recognition
-----
60050a Reference mark position teach
Error when HL-axis, NL-axis of CTR Fly Recognition began zeroing.
-----
60050b Reference mark position teach
Error while HL-axis, NL-axis of CTR Fly Recognition is zeroing.
-----
60050c Reference mark position teach
Error when DD-axis of CTR Fly Recognition began to rotate.
-----
60050d Reference mark position teach
Error while DD-axis of CTR Fly Recognition is rotating.
-----
60050e Reference mark position teach
Error of Data set for XY Beam of CTR Fly Recognition
-----
60050f Reference mark position teach
Error of moving for XY Beam.
-----
600510 Reference mark position teach
Time-out in XY Beam movement
-----
60 0 511 Reference mark position teach
Time-out in communication with Recognition
-----
600512 Reference mark position teach
Error of coordinates calculation of Standard Mark Recognition
-----
600513 Reference mark position teach
Error of moving for XY Beam.
-----
600514 Reference mark position teach
Time-out in XY Beam movement
-----
600515 Reference mark position teach
Time out in communication with Recognition
-----
600601 Nozzle position offset teach
Could not recognize nozzle
Please confirm that Nozzle is placed and exact Nozzle arrangement data is set.
600602 Nozzle position offset teach
Error of Recognition Command response.
-----
EUKYX
3-135199-4100
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
600603 Nozzle position offset teach
Error of coordinates calculation.
-----
600604 Nozzle position offset teach
Error when DD-axis began to rotate.
-----
600605 Nozzle position offset teach
Error while DD-axis is rotating
-----
600606 Nozzle position offset teach
Error when HL-axis and NL-axis began zeroing
-----
600607 Nozzle position offset teach
Error while HL-axis and NL-axis are on zeroing
-----
600608 Nozzle position offset teach
Error of Data set for XY Beam.
-----
600609 Nozzle position offset teach
Error of moving for XY Beam.
-----
60060a Nozzle position offset teach
Time-out in XY Beam movement
-----
60060b Nozzle position offset teach
Time-out in communication with Recognition
-----
600701 Fly recog. Offset teach
Could not recognize Standard Mark Stop
1.Please clean a mark part.
2.Please check whether lighting is on.
600702 Fly recog. Offset teach
Could not recognize Standard Mark Fly
1.Please clean a mark part.
2.Please check whether lighting is on.
600703 Fly recog. Offset teach
Error of Recognition Command Responses in a case of Head Stop Recognition
-----
600704 Fly recog. Offset teach
Error of Recognition Command Responses in a case of Fly Recognition
-----
600705 Fly recog. Offset teach
Error of Coordinates calculation
-----
600706 Fly recog. Offset teach
Error of Data set for XY Beam.
-----