EUKYX-199-4110_G5S2_Instruction_Vol4_E.pdf - 第273页
EUKYX 3-108 199-4100 3.10 Others Error ID Error Name, Description, Cause, and Remedy 4b0 c02 No zzle C onfir mati on Erro r bef ore pi ck up c omp The re main s com pon ent wa s found o n a nozz le dur ing pr odu ct ion.…

EUKYX
3-107199-4100
3.10 Others
Error ID Error Name, Description, Cause, and Remedy
4b0801 Side View Camera operation is abnormal.
Side View Camera was found abnormality while measuring.
There is a possibility of Light Emitter and Receiver broken. Please confirm Error from Log
Request Screen(Unit adjustment -> Side view camera Screen)
4b0802 Side View Camera operation error
The measurement by the side view camera was not completed on time.
Communication connector of Side view camera P.C.B is taken off. Please confirm whether
the items of LS-RLS-S(Device Check -> List) is Yellow. HLS communication cable could not
be connected and such like things.
4b0803 Side View Camera operation error
There is a problem in the values measured by the side view camera.
Light Emitter and Receiver could have flaw and soil. Please clean it up. Please press
[Operation] on the screen(Unit adjustment -> Side view camera -> Detection test Screen)
and confirm whether there is an error
4b0804 Side View Camera operation error
There is a problem in the values measured by the side view camera.
There is a possibility of Side View CameraP.C.B. broken
4b0805 Side View Camera operation error
There is a problem in the values measured by the side view camera.
A small light quantity of Light Emitter. Please exchange Light Emitter.
4b0806 Side View Camera operation error
There is a problem in the values measured by the side view camera.
There is a possibility of Side View Camera P.C.B. broken. Either, Please update Version on
the screen(Unit adjustment -> Side view camera -> Correct data read Screen)
4b0807 Side View Camera operation error
There is a problem in the values measured by the side view camera.
Please confirm Error from Log Request Screen(Unit adjustment -> Side view camera
Screen). Either, please confirm whether the items of LS-RLS-S(Device Check -> List) is
Yellow.
HLS communication cable could not be connected and such like things.
4b0808 Side View Camera operation error
There is a problem in the values measured by the side view camera.
Please confirm Error from Log Request Screen(Unit adjustment -> Side view camera
Screen). Either, please confirm whether the items of LS-RLS-S(Device Check -> List) is
Yellow.
HLS communication cable could not be connected and such like things.
4b0809 Side View Camera operation error
There is a problem in the side view camera.(Strobe Signal did not turn off within
predetermined time.)
Please confirm Error from Log Request Screen(Unit adjustment -> Side view camera
Screen). Either, please confirm whether the items of LS-RLS-S(Device Check -> List) is
Yellow.
HLS communication cable could not be connected and such like things.
4b0c01 Nozzle Confirmation Error before pick up comp (Detect After Placement)
Because a component was found on a nozzle, it stopped after disposal.
The result could have some problems.
Please check placement state on placement step recovery screen.

EUKYX
3-108199-4100
3.10 Others
Error ID Error Name, Description, Cause, and Remedy
4b0c02 Nozzle Confirmation Error before pick up comp
The remains component was found on a nozzle during production.
Please confirm whether there is an error in the P.C.B.
4b0c03 Nozzle Confirmation Error before pick up comp (Detect After Discard)
Because a component was found on a nozzle, it stopped after disposal.
Please confirm and clean up the nozzle if this error continues. And please check the status
of a PCB.
4b0e01 Splicing tape set error
The joint part of splicing tape is not correctly set. Please extract a feeder and check
whether the tape has separated from the guide.
-----
4b1201 Press in error / Insertion error
There is an error with the component pressed in or Insertion
Open safety cover and confirm the component on P.C.B. Please remove it or revise it
4b19ff Zeroing of single axis error
Timeout in zeroing of single axis.
-----
4b2001 P.C.B Height Measurement
Abnormal measured value was detected.
Check the measurement position.
4b2002 P.C.B Height Measurement
Abnormality occurred for communication with a sensor
-----
4b2003 P.C.B Height Measurement
The abnormality number of times of measured value was beyond a set point. Running is
stopped.
-----
4b2004 P.C.B Height Measurement
The abnormality number of times of measured value was beyond a set point.
-----
4b2005 P.C.B Height Measurement
A measurement result is abnormal(measure in arbitrary position)
Check the measurement position.
4b2006 P.C.B Height Measurement
Surpass a measurement range. (+ direction)
-----
4b2007 P.C.B Height Measurement
Surpass a measurement range. (- direction)
-----
4b2008 P.C.B Height Measurement
Detected a curve more than permission values. (+ direction)
-----
4b2009 P.C.B Height Measurement
Detected a curve more than permission values. (- direction)
-----

EUKYX
3-109199-4100
3.10 Others
Error ID Error Name, Description, Cause, and Remedy
4b200a P.C.B Height Measurement
Error of the result measured by a master jig (height)
Check if the master jig (height) has some dirt and foreign particles.
4b200b P.C.B Height Measurement
Failed in wearing height revision.
-----
4b200c P.C.B Height Measurement
An abnormal measurement was detected by the multipoint measurement.
Check the measurement position.
4b200d P.C.B Height Measurement
Recovery by the multipoint measurement failed because the measurement result was
insufficient.
Check the measurement position.
4b 2011 P.C.B Height Measurement
Measurement time-out
-----
4b2081 P.C.B Height Measurement
Abnormality occurred for communication with a sensor
-----
4b2082 P.C.B Height Measurement
Failed in wearing height revision.
-----
4b2083 P.C.B Height Measurement
Measurement time-out
-----
4b2084 P.C.B Height Measurement
The coordinate where the height measurement was impossible was appointed.
Please appoint a coordinate in a measurable range.
4b2101 SSC network abnormal
There is abnormal in SSC network.
Please confirm the cable of SSC network.
4b2102 SSC network abnormal
There is a problem in connection to Servo Amplifier(XY).
(1) Shut down the machine and check the connection between the position board and
amplifier.
(2) Check whether or not the servo amplifiers are damaged.
4b2103 SSC network abnormal
There is a problem in connection to Servo Amplifier(Head).
(1) Shut down the machine and check the connection between the position board and
amplifier.
(2) Check whether or not the servo amplifiers are damaged.
4b2301 Feeder (Servo Error)
Alarm Code:A0 - Internal Parameter Error (Breakdown of Control P.C.B.)
Please replace the feeder. (Do not disconnect the feeder in powering on, otherwise it may
cause the inside data broken.)