EUKYX
1-21199-4100
4.2 Vacuum System
4.2 Vacuum System
4.2.1 Vacuum Pressure Inspection
Cycle : Every Day (Required Time: 1 minute)
Vacuum Pressure
F4A14
Visually check the vacuum pressure.
Vacuum Valve Fully Opened : Min. -93 kPa (Min. 70 cmHg) or more
Running : Min. -60 kPa (Min. 45 cmHg) or more
When the vacuum pressure is insufficient, air may be leaking from the vacuum line or the
vacuum pump may have broken down.
Procedure
Note

EUKYX
1-22199-4100
4.2 Vacuum System
4.2.2 Filter Cleaning
Cycle : Every 3 Months (Required Time : 10 minutes)
Filter Case
C
Filter
F4A15
(1) Remove 4 setscrews fastening the cover at the lower front of the machine and detach the
cover.
(2) Rotate the filter case in Arrow Direction C to detach and then take out the filter.
(3) Blow air to the filter for cleaning.
When the vacuum pressure has dropped during the operation, replace the filter with a new
one.
(4) Attach the cover while pushing it upward and tighten it with the setscrews.
If a clearance is left between the main machine and the cover, the tape will pop out from the
clearance during the operation, causing the machine to breakdown or generate an error.
Procedure
Note
Notice

EUKYX
1-23199-4100
4.3 Component Recognition Camera Section
4.3 Component Recognition Camera Section
4.3.1 Component Recognition Camera Cleaning
NOTICE
Do not put your hand onto the reference mark block.
If too much force is given to the reference mark
block, it may become deformed.
Use a suction force such as a vacuum cleaner for the cleaning.
Do not blow air to any cleaning section with an air gun.
When air is blown, the dirt and dust inside the machine will disperse, causing the recognition
system and the machine to malfunction.
Fiducial Mark Block
Component Recognition Camera
(2 locations)
Every Day Cleaning
Required Time: 4 minutes
Remove the components that have fallen with a
pair of vacuum tweezers and wipe off dust with
a lens cleaning cloth.
F4A16
Notice