EUKYX-199-4110_G5S2_Instruction_Vol4_E.pdf - 第324页
EUKYX 3-159 199-4100 3.14 T est 3 .1 4 Te s t Error ID Error Name, Description, Cause, and Remedy 610 101 Operati on error Operati on error h as occ urred. -----

EUKYX
3-158199-4100
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
604715 Teaching Height of Traverse Chute
The value of Flowmeter is higher than 5.0V.
------
604716 Teaching Height of Traverse Chute
The value of Flowmeter is lower than 4.7V.
------
604717 Teaching Height of Traverse Chute
There is no measured data of Noz 1. It is necessary to measure Noz1 first.
------
604718 Teaching Height of Traverse Chute
Cannot measure it for XY-coord is not defined.
------
604719 Teaching Height of Traverse Chute
Error in Flowing Quantity
------

EUKYX
3-159199-4100
3.14 Test
3.14 Test
Error ID Error Name, Description, Cause, and Remedy
610101 Operation error
Operation error has occurred.
-----

EUKYX
3-160199-4100
3.15 Coplanarity
3.15 Coplanarity
Error ID Error Name, Description, Cause, and Remedy
6b0101 Coplanarity System Error
Communication time-out.
Check the coupling network cable between the Coplanarity unit PC and the main machine.
6b0102 Coplanarity System Error
Command Error
There is a possibility of following error.
1. Coplanarity Unit
2. Software Error
Shut down the device, and turn it on again. Please contact the service when not repaired
even if turns it on again.
6b0103 Coplanarity System Error
Received data Error
There is a possibility of following error.
1. Coplanarity Unit
2. Software Error
Shut down the device, and turn it on again. Please contact the service when not repaired
even if turns it on again.
6b0104 Coplanarity System Error
Sequence Error
There is a possibility of following error.
1. Coplanarity Unit
2. Software Error
Shut down the device, and turn it on again. Please contact the service when not repaired
even if turns it on again.
6b1001 Coplanarity System Error
System error. (1000)
Error in Coplanarity Unit. Shut down the device, and turn it on again. Please contact the
service when not repaired even if turns it on again.
6b1011 Coplanarity System Error
Memory error in unit.(1010)
Error in Coplanarity Unit. Shut down the device, and turn it on again. Please contact the
service when not repaired even if turns it on again.
6b1061 Coplanarity System Error
Laser error.(1060)
Error in Coplanarity Unit. Shut down the device, and turn it on again. Please contact the
service when not repaired even if turns it on again.
6b1071 Coplanarity System Error
Memory error in sensor section. (1070)
Error in Coplanarity Unit. Shut down the device, and turn it on again. Please contact the
service when not repaired even if turns it on again.
6b1081 Coplanarity System Error
Sensor cable not connected. (1080)
Check the connection between the Coplanarity unit PC and the sensor head.