EUKYX-199-4110_G5S2_Instruction_Vol4_E.pdf - 第301页
EUKYX 3-136 199-4100 3.13 Auto T eaching Error ID Error Name, Description, Cause, and Remedy 6 007 07 Fly r ec og. Of f set tea ch Erro r of movi ng for X Y Bea m. ----- 6 007 08 Fl y rec og. O f fset te ach Time -o ut i…

EUKYX
3-135199-4100
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
600603 Nozzle position offset teach
Error of coordinates calculation.
-----
600604 Nozzle position offset teach
Error when DD-axis began to rotate.
-----
600605 Nozzle position offset teach
Error while DD-axis is rotating
-----
600606 Nozzle position offset teach
Error when HL-axis and NL-axis began zeroing
-----
600607 Nozzle position offset teach
Error while HL-axis and NL-axis are on zeroing
-----
600608 Nozzle position offset teach
Error of Data set for XY Beam.
-----
600609 Nozzle position offset teach
Error of moving for XY Beam.
-----
60060a Nozzle position offset teach
Time-out in XY Beam movement
-----
60060b Nozzle position offset teach
Time-out in communication with Recognition
-----
600701 Fly recog. Offset teach
Could not recognize Standard Mark Stop
1.Please clean a mark part.
2.Please check whether lighting is on.
600702 Fly recog. Offset teach
Could not recognize Standard Mark Fly
1.Please clean a mark part.
2.Please check whether lighting is on.
600703 Fly recog. Offset teach
Error of Recognition Command Responses in a case of Head Stop Recognition
-----
600704 Fly recog. Offset teach
Error of Recognition Command Responses in a case of Fly Recognition
-----
600705 Fly recog. Offset teach
Error of Coordinates calculation
-----
600706 Fly recog. Offset teach
Error of Data set for XY Beam.
-----

EUKYX
3-136199-4100
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
600707 Fly recog. Offset teach
Error of moving for XY Beam.
-----
600708 Fly recog. Offset teach
Time-out in XY Beam movement
-----
600709 Fly recog. Offset teach
Time-out of communication with recognition
-----
600801 Teaching Pick-up Position
Please push the Feeder Ready SW
-----
600802 Teaching Pick-up Position
Error of Feeder Mark Recognition
(1)Please clean a mark part.
(2)Please check whether P.E.C. lighting is on.
600803 Teaching Pick-up Position
Feeder connection is set in test mode.
Please set test pattern "OK"
600804 Teaching Pick-up Position
The data of the feeder was not able to be read.
(1)Please take out Feeder and please confirm a connector joint.
(2)Please exchange Feeder.
600805 Teaching Pick-up Position
Time-over of Feeder Mark Recognition Process
-----
600806 Teaching Pick-up Position
Time-out in XY Beam movement
-----
600807 Teaching Pick-up Position
Error of moving for XY Beam.
-----
600808 Teaching Pick-up Position
Error of processing Recognition Stop
-----
600809 Teaching Pick-up Position
Error of processing Light on
-----
60080a Teaching Pick-up Position
Error of processing image capture
-----
600901 Teaching Leaning Nozzle offset
Could not recognize Glass Jig
Please confirm that Glass Jig is set on Glass Jig place.(Check it because there is a
possibility that nozzle is not on head, or vacuum is not "ON".)
600902 Teaching Leaning Nozzle offset
Error of Recognition Command Response
-----

EUKYX
3-137199-4100
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
600903 Teaching Leaning Nozzle offset
Error of coordinates calculation.
-----
600904 Teaching Leaning Nozzle offset
Error of Data set for XY Beam.
-----
600905 Teaching Leaning Nozzle offset
Error of moving for XY Beam.
-----
600906 Teaching Leaning Nozzle offset
Time-out in XY Beam movement
-----
600907 Teaching Leaning Nozzle offset
Time-out of communication with recognition.
-----
600908 Teaching Leaning Nozzle offset
Error of Leaning Nozzle offset teaching
-----
600909 Teaching Leaning Nozzle offset
Error of Noz Select Axis Pos. Offset Teaching
-----
60090A Teaching Leaning Nozzle offset
Noz Select Axis Pos. Offset is out of permission values.
There is a possibility that Head Rotate Theta Axis offset is not correct. / There is a
possibility that Light Emitter and Receiver of Linear measuring Sensor has flaw and soil /
There is a possibility that Nozzle is damaged. / There is a possibility that Head has some
problem.
60090B Teaching Leaning Nozzle offset
Could not measure correctly on Noz Select Axis Pos. Offset Teaching.
There is a possibility that Head Rotate Theta Axis offset is not correct. / There is a
possibility that Light Emitter and Receiver of Linear measuring Sensor has flaw and soil /
There is a possibility that Nozzle is damaged. / There is a possibility that Head has some
problem.
601001 Master nozzle level offset teach
Error is detected before Side View Camera measurement began
-----
601002 Master nozzle level offset teach
Error of NS-axis movement
-----
601003 Master nozzle level offset teach
Error of DD-axis movement
-----
601004 Master nozzle level offset teach
Time-out of NS-axis movement
-----