EUKYX-199-4110_G5S2_Instruction_Vol4_E.pdf - 第205页

EUKYX 3-41 199-4100 3.3 Conveyor Error ID Error Name, Description, Cause, and Remedy 424 0 03 Stop per mov ement Error Time O ver of th e upwa rd movem ent of s top per 1 .Chec k ou t the P .C.B. bet we en sto ppe r and …

100%1 / 363
EUKYX
3-40199-4100
3.3 Conveyor
Error ID Error Name, Description, Cause, and Remedy
423608 Error in NR-L2 axis
Motor disconnection of NR-L2 axis was detected
Disconnection to motor was detected. (Only stop mode)
Check the motor wiring.
423609 Error in NR-L2 axis
Error in control power voltage of NR-L2 axis
Control power for driver dropped. Check out the Power supply line.(24V Line)
42360a Error in NR-L2 axis
Reserved Code
Reserved Function of driver. Please make inquiries when error is detected.
42360b Error in NR-L2 axis
Reserved Code
Reserved Function of driver. Please make inquiries when error is detected.
42360c Error in NR-L2 axis
Reserved Code
Reserved Function of driver. Please make inquiries when error is detected.
42360d Error in NR-L2 axis
Reserved Code
Reserved Function of driver. Please make inquiries when error is detected.
42360e Error in NR-L2 axis
Reserved Code
Reserved Function of driver. Please make inquiries when error is detected.
42360f Error in NR-L2 axis
System Error on NR-L2 axis
System Error of internal driver. Driver error is supposed if this problem happens frequently.
423610 Error in NR-L2 axis
Communication Error on NR-L2 axis
1. Confirm connection to communication cable.
2. Confirm Power supply(24V).
3. Confirm the communication setting of PCI board.
4. Confirm the address of driver and communication rate setting.
5. Confirm Firmware of Driver.
424001 Stopper movement Error
Stop sensor was detected before positioning(R) stopper
There is a possibility that P.C.B. is pulled and raised in Stopper. Please confirm P.C.B.
stopping position.
424002 Stopper movement Error
Positoning(R) stopper was not completed within predetermined time.
1. Check out the P.C.B. between stopper and conveyor
2. Error in Up/Down detection sensor. Check out the sensor input
3. Disconnection, Error of Movement output. Please check Stopper by manual
movement if sensor input is proper.
4. Please set speed again by adjusting speed control when stopper is slow.
EUKYX
3-41199-4100
3.3 Conveyor
Error ID Error Name, Description, Cause, and Remedy
424003 Stopper movement Error
Time Over of the upward movement of stopper
1.Check out the P.C.B. between stopper and conveyor
2. Error in Up/Down detection sensor. Check out the sensor input
3.Disconnection, Error of Movement output. Please check Stopper by manual movement if
sensor input is proper.
4. Please set speed again by adjusting speed control when stopper is slow.
424004 Stopper movement Error
Input stop sensor is detected before input stopper goes up.
PCB has reached the stopper. Please confirm that the start position for placement PCB is
correct.
424005 Stopper movement Error
Output stop sensor is detected before output stopper goes up.
PCB has reached the stopper. Please confirm that the start position for placement PCB is
correct.
424101 Detection of Input conveyor P.C.B.
P.C.B. was detected before starting placement from input machine
Please remove indefinite P.C.B. from conveyor. Confirm whether P.C.B. is not detected
before P.C.B. transfer.
424102 Detection of Input conveyor P.C.B.
P.C.B. on Input conveyor is existing
Remove P.C.B. from Conveyor.
424201 Detection of output conveyor P.C.B.
P.C.B. was detected before starting output for output machine
Remove P.C.B. from Conveyor.
424202 Detection of output conveyor P.C.B.
The output for Output machine is completed, but P.C.B. on conveyor was detected
Remove P.C.B. from Conveyor.
424301 Detection of positioning conveyor(R) P.C.B.
No P.C.B. on conveyor
Output P.C.B. is not detected. Please confirm whether P.C.B. is detected correctly or not.
424302 Detection of positioning conveyor(R) P.C.B.
The placement was completed, but P.C.B. was not detected.
Placed P.C.B. is not detected. Please confirm whether P.C.B. is detected correctly or not.
425101 Detection of Input conveyor sensor
Decrease sensor was detected before starting
Remove P.C.B. from Input Conveyor.
425102 Detection of Input conveyor sensor
Decrease sensor was not detected before starting
Placing P.C.B. is not found internal machine.
1. Please put P.C.B. on the sensor
2. Because there is a possibility of P.C.B. falling, please confirm the width of
conveyor.
425103 Detection of Input conveyor sensor
Stop sensor was detected before starting
Remove P.C.B. from Input Conveyor.
EUKYX
3-42199-4100
3.3 Conveyor
Error ID Error Name, Description, Cause, and Remedy
425104 Detection of Input conveyor sensor
Stop sensor was Not detected before starting
Placing P.C.B. is not found internal machine.
1. Please put P.C.B. on the sensor
2. Because there is a possibility of P.C.B. falling, please confirm the width of
conveyor.
425105 Detection of Input conveyor sensor
P.C.B. on decrease sensor was detected after movement completion
Remove P.C.B. from Input Conveyor.
425106 Detection of Input conveyor sensor
P.C.B. on decrease sensor was not detected after movement completion
Please check whether P.C.B. is detected correctly.
Confirm whether the sensor doesn’t have Error.
425107 Detection of Input conveyor sensor
P.C.B. on stop sensor was detected after movement completion
Remove P.C.B. from Input Conveyor.
425108 Detection of Input conveyor sensor
P.C.B. on stop sensor was not detected after movement completion
Please check whether P.C.B. is detected correctly.
Check whether the sensor doesn’t have Error.
425109 Detection of Input conveyor sensor
P.C.B. on Input conveyor was detected
Remove P.C.B. from Conveyor.
42510a Detection of Input conveyor sensor
P.C.B. on Input conveyor was not detected
Please check whether P.C.B. is detected correctly. Check whether the sensor doesn’t have
Error.
42510b Detection of Input conveyor sensor
2 P.C.B. pieces on conveyor exist.
1. Remove it if unnecessary P.C.B. exists, when checking P.C.B. on Conveyor.
2. Please return PCB to Stop sensor of input conveyor when PCB on input conveyor
is taken on positioning conveyor.
42510c Detection of Input conveyor sensor
P.C.B. on sensor was detected in the state of not placing P.C.B.
There is a possibility whether P.C.B. is inserted or P.C.B. arrived before detecting signals.
42510d Detection of Input conveyor sensor
Disengaged P.C.B. of Input conveyor
Possible to driver continuously.
Please confirm the state of P.C.B. if it is not removed purposely
42510e Detection of Input conveyor sensor
P.C.B. was not detected when placement was completed
P.C.B. from Input Machine is not received and sent.
Please confirm whether P.C.B. on Input conveyor is caught.