EUKYX-199-4110_G5S2_Instruction_Vol4_E.pdf - 第212页
EUKYX 3-48 199-4100 3.3 Conveyor Error ID Error Name, Description, Cause, and Remedy 4 2 8101 Line P CB transfer error Time-out of Pl acement Line PCB t rans fer wa s not c ompl eted i n pres cri be d time. 1 . The re is…

EUKYX
3-47199-4100
3.3 Conveyor
Error ID Error Name, Description, Cause, and Remedy
42710d Detection of Output conveyor sensor
P.C.B. was not inserted into output conveyor
Please Remove P.C.B. inserted.
427201 Output conveyor timeout
Placement was not completed within predetermined time.
1. There is a possibility that PCB is caught, or dropped from Conveyor. Please check
the above conveyor.
2. The state of PCB memory on the conveyor differs from the state of taking. Please
clear the PCB memory in the edit screen when if it is. Or, return the removed PCB.
427202 Output conveyor timeout
Output was not completed within predetermined time.
1. There is a possibility that PCB is caught, or dropped from Conveyor. Please check
the transition with Output Machine.
2. Please clear the PCB memory information in the edit screen on the output conveyor
if it is. Or, return the removed PCB.
427301 Output Conveyor Error
Error while output conveyor is moving.
-----
427401 External Enhancing Conveyer Error
Error in Placement from Input Machine.
PCB is not placed in Device. Please check External Enhancing Conveyor.
1. Whether Emergency stop is pressed
2. Whether Safety Cover is open
3. Whether Breaker is falling down
If PCB is on Middle Conveyor, whether remove it, or put it on Input conveyor.
427402 External Enhancing Conveyer Error
Error in Output for Output Machine.
PCB is not outputted from Device. Please check External Enhancing conveyor.
1. Whether Emergency stop is pressed
2. Whether Safety Cover is open
3. Whether Breaker is falling down
428001 Error in the communication of P.C.B. transfer
Input Machine signal cutting
A signal of work request for the output machine was cut off while P.C.B. is placing.
1. Please check the transfer method of Input Machine.
2. Check the connected cable.
428002 Error in the communication of P.C.B. transfer
Output Machine signal cutting
A signal of work request for the output machine was cut off while P.C.B. is placing.
1. Please check the transfer method of output Machine.
2. Check the connected cable.

EUKYX
3-48199-4100
3.3 Conveyor
Error ID Error Name, Description, Cause, and Remedy
428101 Line PCB transfer error
Time-out of Placement
Line PCB transfer was not completed in prescribed time.
1. There is a possibility that PCB is caught. Please Check the Conveyor.
2. Please confirm whether Connect cable is normally connected or not.
428201 Transfer Error between Devices
Time-out of starting Input Machine
Could not start Output from Input Machine. Error in Input Machine.
428202 Transfer Error between Devices
Time-out of starting Output Machine
Could not receiver Start Signal from Output Machine. Error in output Machine.
428203 Transfer Error between Devices
Output Machine Error
Error during placement of Output Machine. Transfer will be stopped.
429001 Manual transfer Error
Time-out in Conveyor
The Conveyor didn't stop within predetermined time.
Please confirm the state of transfer driver.
42a001 Shuttle Conveyor Communication Error
Failed in getting Shuttle Conveyor Control Information.
Communication Error between CPU1 and CPU2 has occurred.
Please restart Machine.
42a101 Detect Suttle Conveyor Sensor in Input side
Decrease Sensor is detected before starting to operate.
Please remove PCB from Shuttle Conveyor.
42a102 Detect Suttle Conveyor Sensor in Input side
Decrease Sensor is not detected before starting to operate.
PCB to insert is not found inner Machine.
1. Please put PCB on Sensor.
2. There is a possibility that PCB drops. Please check out Conveyor width.
42a103 Detect Suttle Conveyor Sensor in Input side
Stop Sensor is detected before starting to operate.
Please remove PCB from Shuttle Conveyor.
42a104 Detect Suttle Conveyor Sensor in Input side
Stop Sensor is not detected before starting to operate.
PCB to insert is not found inner Machine.
1. Please confirm whether PCB is detected by Sensor or not.
2. There is a possibility that PCB drops. Please check out Conveyor width.
42a105 Detect Suttle Conveyor Sensor in Input side
PCB is detected from Decrease Sensor after finishing completely.
Please remove PCB from Shuttle Conveyor.
42a106 Detect Suttle Conveyor Sensor in Input side
PCB is not detected from Decrease Sensor after finishing completely.
Please confirm whether PCB is detected properly. And confirm whether Sensor did not
break down.

EUKYX
3-49199-4100
3.3 Conveyor
Error ID Error Name, Description, Cause, and Remedy
42a107 Detect Suttle Conveyor Sensor in Input side
PCB is detected from Stop Sensor after finishing completely.
Please remove PCB from Shuttle Conveyor.
42a108 Detect Suttle Conveyor Sensor in Input side
PCB is not detected from Stop Sensor after finishing completely.
Please confirm whether PCB is detected properly. And confirm whether Sensor did not
break down.
42a109 Detect Suttle Conveyor Sensor in Input side
PCB is detected from Shuttle Conveyor.
Please remove PCB from Conveyor.
42a10a Detect Suttle Conveyor Sensor in Input side
PCB is not detected from Shuttle Conveyor.
Please confirm whether PCB is detected properly. And confirm whether Sensor did not
break down.
42a10b Detect Suttle Conveyor Sensor in Input side
PCB has not got to shuttle Conveyor from Input Machine.
PCB from Input Machine is not transferred.
Please confirm whether PCB on the conveyor for Input machine is caught
42a10c Detect Suttle Conveyor Sensor in Input side
PCB is still on Shuttle conveyor.
To insert into inner Machine is not completed. Please check PCB position.
42a10d Detect Suttle Conveyor Sensor in Input side
PCB on Shuttle conveyor is gone.
It is possible to operate continuously.
Please confirm whether PCB went off its position if PCB is not removed on purpose.
42a10e Detect Suttle Conveyor Sensor in Input side
PCB on Shuttle conveyor is changed.
PCB is inserted while not possible to be inserted. Please remove inserted PCB.
42a10f Detect Suttle Conveyor Sensor in Input side
The Sensor of Shuttle Conveyor is detected from both sides.
There is a possibility that two pieces of PCB are inserted. Please remove an uncertain PCB.
Please setup Timing to transfer PCB from Input machine.
42a201 Time-out of Shuttle Conveyor in Input side
Time-out is occurred during insert mode from Input Machine.
There is a possibility that PCB is stopped on conveyor.
1. Please confirm PCB position.
2. Please confirm whether Conveyor Width is fit.
3. Please setup Input Conveyor Timer Value of System settings, and adjust insert
time.
42a202 Time-out of Shuttle Conveyor in Input side
Time-out is occurred during insert mode for Inner Machine.
PCB is stopped on Conveyor. Please confirm PCB Position.
1. Please confirm whether Transit Position from shuttle Conveyor is proper.
2. Please confirm whether Conveyor Width is fit.