EUKYX 2-25 199-4100 3.2 Machine Information list Err C od e (HEX ) Di spl ay Are a A Di spl ay Are a B 8 01 101 Noz zle dia meter confirmation The d isag reem ent of t he noz zle diam eter wa s dete cte d wi th the si de…

100%1 / 363
EUKYX
2-24199-4100
3.2 Machine Information list
Err Code
(HEX)
Display Area A Display Area B
800617 Alternated Feeder
Alarm Code:E0 - (1) Damaged cover tape/ (2) Cover tape jammed in
the storage/ (3) Splicing section peeling off
800618 Alternated Feeder Alarm Code:E1 - Cover tape peeling off error (Get caught up)
800619 Alternated Feeder
Alarm Code:E2 - Origin Position Checking Error (Excessively out of
the origin during servo ON)
80061a Alternated Feeder
Alarm Code:E3 - (1) No supplied history/ (2) Dirty splicing detection
sensor (dust adhesion)
80061b Alternated Feeder
Alarm Code:E4 - Positioning Completion Timeout (Foreign
substances in the sprocket wheel)
80061c Alternated Feeder Alarm Code:E5 - Redundant Order Error (A feeding error may occur.)
80061d Alternated Feeder Alarm Code:E6 - Lane Change Timeout Error
80061e Alternated Feeder Alarm Code:E7 - Servo ON Timeout
80061f Alternated Feeder Obverse/Reverse inspection detect (Sensor)
800801
Start Auto Recovery
Mode
Shortage of component
800802
Start Auto Recovery
Mode
Splice waiting
800803
Start Auto Recovery
Mode
Comp. Vertical (Sensor)
800804
Start Auto Recovery
Mode
Comp. Thickness (Sensor)
800805
Start Auto Recovery
Mode
Comp. Missing (Sensor)
800806
Start Auto Recovery
Mode
Comp. Recog. Error (recog.)
800807
Start Auto Recovery
Mode
Comp. Missing (Recog)
800808
Start Auto Recovery
Mode
Coplanarity Check Error
800809
Start Auto Recovery
Mode
Feeder Alarm
80080a
Start Auto Recovery
Mode
Feeder unloading
80080b
Start Auto Recovery
Mode
Device Op is stopped because Feeder is not loaded.
80080c
Start Auto Recovery
Mode
Etc
80080d
Start Auto Recovery
Mode
Obverse/Reverse inspection error (Sensor)
80080e
Start Auto Recovery
Mode
SL feeder loading operation
80080f
Start Auto Recovery
Mode
Following tape of non-registration was detected. Please operate the
component supply.
800810
Start Auto Recovery
Mode
Following tape was detected. Please verify the component.
80 0 811
Start Auto Recovery
Mode
Placement cycles of both heads are postponed together for SL
feeder loading.
800902
Alarm for Shortage of
Comp.
Few components to feed.
EUKYX
2-25199-4100
3.2 Machine Information list
Err Code
(HEX)
Display Area A Display Area B
801101
Nozzle diameter
confirmation
The disagreement of the nozzle diameter was detected with the side
view camera. There is a possibility of the side view camera dirt and
the nozzle dirt, please confirm whether a different nozzle has
adhered.
801b01 Lightning Surge alarm Lightning Surge Protector works; Q204.
801b02 Lightning Surge alarm Lightning Surge Protector works; Q204. Running continue.
801b03 Lightning Surge alarm
Protective Fuse error of lightning Surge Protector. Exchange the
fuse.
801c05 Information Warm start mode was canceled.
801c06 Information The machine stopped by the automatic stop function.
801c07 Information The machine will be stopped by start protect.
801c08 Information
The machine will be stopped by Component Remain Stop Mode.
(CompRem is less than the number of the whole PCB use)
801c09 Information
The machine will be stopped by Component Remain Stop Mode.
(CompRem is less than the number of the whole Product PCB use)
801c0a Information A stop request by Component Remain Stop Mode was canceled.
801c0b Information Trash box fill up.
801c0c Information Trash box of Cart#1 is fill up.
801c0d Information Trash box of Cart#2 is fill up.
801c0f Information
Delay has occurred in the communications processing inside
machine.
801c10 Information
The machine operation was stopped by a function of the P.C.B.
counter stop mode.
801c11 Information
The component skip is set up. It is not placed with the components
by which a skip setup was carried out.
801c12 Information
The recognition image saved is over 200 MB. Please delete an
unnecessary file.
801c13 Information
Since the database of the component library was damaged,
restoration processing was performed.
801c14 Information
Since the database of the test library was damaged, restoration
processing was performed.
801c15 Information
The recognition image saved is over 400 MB. Please delete an
unnecessary file.
801c16 Information The appointed PCB was skipped.
801c17 Information The program change was completed.
801c18 Information
The machine implemented parts picked up it by an abnormal stop.
(Detecting pickup miss Cmpnt)
801c1d Information
Memories are insufficient. Since there is a possibility that an
operation screen may hang-up, please reboot the machine.
801c1e Information The program change was completed.
802001 Alarm for Splicing
The feeder is running short of the component to feed. Please
prepare for Splicing, and remove the cover tape from the storage
section.
802101
Feeder Maintenance
alarm
The total number of feeder's shots reached a previous notice setting
number.
802102
Feeder Maintenance
alarm
The feeder adsorption rate decreased and exceeded the previous
notice setting number.
802103
Feeder Maintenance
alarm
The total number of feeder's shots reached a previous notice setting
number.
EUKYX
2-26199-4100
3.2 Machine Information list
Err Code
(HEX)
Display Area A Display Area B
802104
Feeder Maintenance
alarm
The feeder adsorption rate decreased and exceeded the previous
notice setting number.
802201 ACV Information
ACV Check Error. Component ID on the feeder is not same as one
specified by current program.
802202 ACV Information
Device (Block1) Cannot clear Clamp for feeder communication.
Please operate it again later.
802203 ACV Information
Device (Block2) Cannot clear Clamp for feeder communication.
Please operate it again later.
802204 ACV Information
Device (Block1) Cannot clear Clamp for receiving the result of ACV
Check Error. Please operate it again later.
802205 ACV Information
Device (Block2) Cannot clear Clamp for receiving the result of ACV
Check Error. Please operate it again later.
802206 ACV Information
Device (Block1) Time-out for receiving the result of ACV Check
Error. Please take out Feeder and then take it in again.
802207 ACV Information
Device (Block2) Time-out for receiving the result of ACV Check
Error. Please take out Feeder and then take it in again.
802208 ACV Information
Device (Block1) Time-out of Feeder communication. Please take out
Feeder and then take it in again.
802209 ACV Information
Device (Block2) Time-out of Feeder communication. Please take out
Feeder and then take it in again.
802301
Splicing No Check
Alarm
The seam passed the detection sensor as unregistered splicing.
Please register the splicing.
802401
Feeder Cover Tape
filled up alarm
The storage section of Cover Tape filled was detected. Please
remove Tape from internal storage section.
802501
Feeder Communication
Error
Failed to displaying Operational Panel. Please put the Cart down, or
pull out and insert Feeder.
802502
Feeder Communication
Error
The communication processing of Feeder was not done in prescribed
time.
802601
Side view camera
sensor
To set synchronized counting position of Head1 is failed.
802602
Side view camera
sensor
To set synchronized counting position of Head2 is failed.
802603
Side view camera
sensor
To reset DD origin position of Head1 is failed.
802604
Side view camera
sensor
To reset DD origin position of Head2 is failed.
802701
Comp Time Limit
Manage
Moisture deadline of component is approaching.
In preparation for the moisture expired, please prepare a new
component.
802702
Comp Time Limit
Manage
Since the moisture deadline of the component has passed, the
device will stop dispensing.
803001 FAN Stop alarm Fan rotation error of the case (Block2). Please clean up Fan.
803002 FAN Stop alarm Fan rotation error of the case (Block1). Please clean up Fan.
803003 FAN Stop alarm Fan rotation error of the power G4 (Upper). Please clean up Fan.
803004 FAN Stop alarm Fan rotation error of the power G4 (Rear). Please clean up Fan.
803005 FAN Stop alarm Fan rotation error of the roof (Left). Please clean up Fan.
803006 FAN Stop alarm Fan rotation error of the roof (Left). Please clean up Fan.
803028 FAN Stop alarm Fan rotation error of Control Box. Clean up Fan.
803101
Feeder Feeding Pitch
Correction
Auto Correction is executed for Feeder Feeding Pitch is out of
position.
803201
SL feeder loading
operation
Because Recovery Mode is "Stop Auto Run", loading of the following
tape was not carried out.