EUKYX 2-24 199-4100 3.2 Machine Information list Err C od e (HEX ) Di spl ay Are a A Di spl ay Are a B 8 0 0 6 17 Alternated Feeder Ala rm Co de: E0 - ( 1 ) Dama ged c over t ape / ( 2) C over ta pe jam med in the s tora…

EUKYX
2-23199-4100
3.2 Machine Information list
Err Code
(HEX)
Display Area A Display Area B
800301
Warning: Decreasing of
Comp. Hdlg. Rate (For
Nozzle.)
Nozzle message rate :
800302
Warning: Decreasing of
Comp. Hdlg. Rate (For
Nozzle.)
The rate of nozzle adsorption fell. A cycle stop is carried out.
800401
Warning: Decreasing of
Comp. Hdlg. Rate (For
Fdr.)
Feeder message rate :
800402
Warning: Decreasing of
Comp. Hdlg. Rate (For
Fdr.)
The rate of nozzle adsorption fell. A cycle stop is carried out.
800505
Alternated Tray
Magazine Axis
Shortage of component
800601 Alternated Feeder Shortage of component
800602 Alternated Feeder Splice waiting
800603 Alternated Feeder Comp. Vertical (Sensor)
800604 Alternated Feeder Comp. Thickness (Sensor)
800605 Alternated Feeder Comp. Missing (Sensor)
800606 Alternated Feeder Comp. Recog. Error (recog.)
800607 Alternated Feeder Comp. Missing (Recog)
800608 Alternated Feeder Coplanarity Check Error
800609 Alternated Feeder
The feeder at the alternation destination is invalid. Please set it
effectively.
80060a Alternated Feeder Feeder unloading
80060b Alternated Feeder Returned to the priority feeder
80060c Alternated Feeder It was alternated.
80060d Alternated Feeder Feeder Alarm
80060e Alternated Feeder
Alarm Code:A0 - Internal Parameter Error (Breakdown of Control
P.C . B . )
80060f Alternated Feeder
Alarm Code:A1 - Over Current Error (Foreign substances in the tape
feeding drive section)
800610 Alternated Feeder
Alarm Code:A4 - Main Circuit Power Supply Error (Please check the
power supply voltage.) (G04)
80 0 611 Alternated Feeder Alarm Code:A5 - Fault Speed Error (Tape catching)
800612 Alternated Feeder
Alarm Code:A7 - Fault Load Error (Tape twisting, Catching foreign
substances)
800613 Alternated Feeder
Alarm Code:A8 - Encoder Error (Breaking wire, Breakdown of control
P.C.B. and Defective servo motor)
800614 Alternated Feeder Alarm Code:Ab - System Error
800615 Alternated Feeder Alarm Code:Ac - Reckless Run Detection Error
800616 Alternated Feeder Alarm Code:Ad - Excessive deviation in position
3.2 Machine Information list
The following is the machine information list by error code.

EUKYX
2-24199-4100
3.2 Machine Information list
Err Code
(HEX)
Display Area A Display Area B
800617 Alternated Feeder
Alarm Code:E0 - (1) Damaged cover tape/ (2) Cover tape jammed in
the storage/ (3) Splicing section peeling off
800618 Alternated Feeder Alarm Code:E1 - Cover tape peeling off error (Get caught up)
800619 Alternated Feeder
Alarm Code:E2 - Origin Position Checking Error (Excessively out of
the origin during servo ON)
80061a Alternated Feeder
Alarm Code:E3 - (1) No supplied history/ (2) Dirty splicing detection
sensor (dust adhesion)
80061b Alternated Feeder
Alarm Code:E4 - Positioning Completion Timeout (Foreign
substances in the sprocket wheel)
80061c Alternated Feeder Alarm Code:E5 - Redundant Order Error (A feeding error may occur.)
80061d Alternated Feeder Alarm Code:E6 - Lane Change Timeout Error
80061e Alternated Feeder Alarm Code:E7 - Servo ON Timeout
80061f Alternated Feeder Obverse/Reverse inspection detect (Sensor)
800801
Start Auto Recovery
Mode
Shortage of component
800802
Start Auto Recovery
Mode
Splice waiting
800803
Start Auto Recovery
Mode
Comp. Vertical (Sensor)
800804
Start Auto Recovery
Mode
Comp. Thickness (Sensor)
800805
Start Auto Recovery
Mode
Comp. Missing (Sensor)
800806
Start Auto Recovery
Mode
Comp. Recog. Error (recog.)
800807
Start Auto Recovery
Mode
Comp. Missing (Recog)
800808
Start Auto Recovery
Mode
Coplanarity Check Error
800809
Start Auto Recovery
Mode
Feeder Alarm
80080a
Start Auto Recovery
Mode
Feeder unloading
80080b
Start Auto Recovery
Mode
Device Op is stopped because Feeder is not loaded.
80080c
Start Auto Recovery
Mode
Etc
80080d
Start Auto Recovery
Mode
Obverse/Reverse inspection error (Sensor)
80080e
Start Auto Recovery
Mode
SL feeder loading operation
80080f
Start Auto Recovery
Mode
Following tape of non-registration was detected. Please operate the
component supply.
800810
Start Auto Recovery
Mode
Following tape was detected. Please verify the component.
80 0 811
Start Auto Recovery
Mode
Placement cycles of both heads are postponed together for SL
feeder loading.
800902
Alarm for Shortage of
Comp.
Few components to feed.

EUKYX
2-25199-4100
3.2 Machine Information list
Err Code
(HEX)
Display Area A Display Area B
801101
Nozzle diameter
confirmation
The disagreement of the nozzle diameter was detected with the side
view camera. There is a possibility of the side view camera dirt and
the nozzle dirt, please confirm whether a different nozzle has
adhered.
801b01 Lightning Surge alarm Lightning Surge Protector works; Q204.
801b02 Lightning Surge alarm Lightning Surge Protector works; Q204. Running continue.
801b03 Lightning Surge alarm
Protective Fuse error of lightning Surge Protector. Exchange the
fuse.
801c05 Information Warm start mode was canceled.
801c06 Information The machine stopped by the automatic stop function.
801c07 Information The machine will be stopped by start protect.
801c08 Information
The machine will be stopped by Component Remain Stop Mode.
(CompRem is less than the number of the whole PCB use)
801c09 Information
The machine will be stopped by Component Remain Stop Mode.
(CompRem is less than the number of the whole Product PCB use)
801c0a Information A stop request by Component Remain Stop Mode was canceled.
801c0b Information Trash box fill up.
801c0c Information Trash box of Cart#1 is fill up.
801c0d Information Trash box of Cart#2 is fill up.
801c0f Information
Delay has occurred in the communications processing inside
machine.
801c10 Information
The machine operation was stopped by a function of the P.C.B.
counter stop mode.
801c11 Information
The component skip is set up. It is not placed with the components
by which a skip setup was carried out.
801c12 Information
The recognition image saved is over 200 MB. Please delete an
unnecessary file.
801c13 Information
Since the database of the component library was damaged,
restoration processing was performed.
801c14 Information
Since the database of the test library was damaged, restoration
processing was performed.
801c15 Information
The recognition image saved is over 400 MB. Please delete an
unnecessary file.
801c16 Information The appointed PCB was skipped.
801c17 Information The program change was completed.
801c18 Information
The machine implemented parts picked up it by an abnormal stop.
(Detecting pickup miss Cmpnt)
801c1d Information
Memories are insufficient. Since there is a possibility that an
operation screen may hang-up, please reboot the machine.
801c1e Information The program change was completed.
802001 Alarm for Splicing
The feeder is running short of the component to feed. Please
prepare for Splicing, and remove the cover tape from the storage
section.
802101
Feeder Maintenance
alarm
The total number of feeder's shots reached a previous notice setting
number.
802102
Feeder Maintenance
alarm
The feeder adsorption rate decreased and exceeded the previous
notice setting number.
802103
Feeder Maintenance
alarm
The total number of feeder's shots reached a previous notice setting
number.