EUKYX-199-4110_G5S2_Instruction_Vol4_E.pdf - 第300页

EUKYX 3-135 199-4100 3.13 Auto T eaching Error ID Error Name, Description, Cause, and Remedy 600603 Nozzle position offset teach Error of coordinat es calculation . ----- 600604 Nozzle position offset teach Erro r when D…

100%1 / 363
EUKYX
3-134199-4100
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
600509 Reference mark position teach
Error of the movement of Jig store of CTR Fly Recognition
-----
60050a Reference mark position teach
Error when HL-axis, NL-axis of CTR Fly Recognition began zeroing.
-----
60050b Reference mark position teach
Error while HL-axis, NL-axis of CTR Fly Recognition is zeroing.
-----
60050c Reference mark position teach
Error when DD-axis of CTR Fly Recognition began to rotate.
-----
60050d Reference mark position teach
Error while DD-axis of CTR Fly Recognition is rotating.
-----
60050e Reference mark position teach
Error of Data set for XY Beam of CTR Fly Recognition
-----
60050f Reference mark position teach
Error of moving for XY Beam.
-----
600510 Reference mark position teach
Time-out in XY Beam movement
-----
60 0 511 Reference mark position teach
Time-out in communication with Recognition
-----
600512 Reference mark position teach
Error of coordinates calculation of Standard Mark Recognition
-----
600513 Reference mark position teach
Error of moving for XY Beam.
-----
600514 Reference mark position teach
Time-out in XY Beam movement
-----
600515 Reference mark position teach
Time out in communication with Recognition
-----
600601 Nozzle position offset teach
Could not recognize nozzle
Please confirm that Nozzle is placed and exact Nozzle arrangement data is set.
600602 Nozzle position offset teach
Error of Recognition Command response.
-----
EUKYX
3-135199-4100
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
600603 Nozzle position offset teach
Error of coordinates calculation.
-----
600604 Nozzle position offset teach
Error when DD-axis began to rotate.
-----
600605 Nozzle position offset teach
Error while DD-axis is rotating
-----
600606 Nozzle position offset teach
Error when HL-axis and NL-axis began zeroing
-----
600607 Nozzle position offset teach
Error while HL-axis and NL-axis are on zeroing
-----
600608 Nozzle position offset teach
Error of Data set for XY Beam.
-----
600609 Nozzle position offset teach
Error of moving for XY Beam.
-----
60060a Nozzle position offset teach
Time-out in XY Beam movement
-----
60060b Nozzle position offset teach
Time-out in communication with Recognition
-----
600701 Fly recog. Offset teach
Could not recognize Standard Mark Stop
1.Please clean a mark part.
2.Please check whether lighting is on.
600702 Fly recog. Offset teach
Could not recognize Standard Mark Fly
1.Please clean a mark part.
2.Please check whether lighting is on.
600703 Fly recog. Offset teach
Error of Recognition Command Responses in a case of Head Stop Recognition
-----
600704 Fly recog. Offset teach
Error of Recognition Command Responses in a case of Fly Recognition
-----
600705 Fly recog. Offset teach
Error of Coordinates calculation
-----
600706 Fly recog. Offset teach
Error of Data set for XY Beam.
-----
EUKYX
3-136199-4100
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
600707 Fly recog. Offset teach
Error of moving for XY Beam.
-----
600708 Fly recog. Offset teach
Time-out in XY Beam movement
-----
600709 Fly recog. Offset teach
Time-out of communication with recognition
-----
600801 Teaching Pick-up Position
Please push the Feeder Ready SW
-----
600802 Teaching Pick-up Position
Error of Feeder Mark Recognition
(1)Please clean a mark part.
(2)Please check whether P.E.C. lighting is on.
600803 Teaching Pick-up Position
Feeder connection is set in test mode.
Please set test pattern "OK"
600804 Teaching Pick-up Position
The data of the feeder was not able to be read.
(1)Please take out Feeder and please confirm a connector joint.
(2)Please exchange Feeder.
600805 Teaching Pick-up Position
Time-over of Feeder Mark Recognition Process
-----
600806 Teaching Pick-up Position
Time-out in XY Beam movement
-----
600807 Teaching Pick-up Position
Error of moving for XY Beam.
-----
600808 Teaching Pick-up Position
Error of processing Recognition Stop
-----
600809 Teaching Pick-up Position
Error of processing Light on
-----
60080a Teaching Pick-up Position
Error of processing image capture
-----
600901 Teaching Leaning Nozzle offset
Could not recognize Glass Jig
Please confirm that Glass Jig is set on Glass Jig place.(Check it because there is a
possibility that nozzle is not on head, or vacuum is not "ON".)
600902 Teaching Leaning Nozzle offset
Error of Recognition Command Response
-----