EUKYX 3-87 199-4100 3.8 Automatic Adjustment Error ID Error Name, Description, Cause, and Remed y 4 9 6 11 0 Co nveyor Wid th W1 Error Syst em set up of Con veyor Wid th W1 is not c omp lete d. Dri ver ha s not c ompl et…

100%1 / 363
EUKYX
3-86199-4100
3.8 Automatic Adjustment
Error ID Error Name, Description, Cause, and Remedy
49079b Nozzle set up
To capture a image with component recognizing camera is not complete with the
predetermined time.
-----
49079c Nozzle set up
Error in recognition of nozzle position.
-----
49079d Nozzle set up
Time-out of recognition of nozzle position.
-----
49079e Nozzle set up
Failed in nozzle position teaching. Please confirm Nozzle ID, and then replace a nozzle.
-----
49079f Nozzle set up
To set nozzle position data failed.
-----
4907A0 Nozzle set up
The nozzle stocker which is not for replace exists on input position.
Please perform all zeroing.
490801 Program -change linked operation
Program-change linked operation has not finished within appointed time.
-----
496001 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W1-axis operating.
Please remove the Backup Pin\Jig from Backup Base. Or, confirm whether Sensor has error
or not.
496002 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W2-axis operating.
Please remove the Backup Pin\Jig from Backup Base. Or, confirm whether Sensor has error
or not.
496003 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W3-axis operating
Please remove the Backup Pin\Jig from Backup Base. Or, confirm whether Sensor has error
or not.
496101 Conveyor Width W1 Error
Drive Alarm during Conveyor Width W1 axial operation.
Confirm reset Method of detailed Sub-system error counts of Alarm.
496102 Conveyor Width W1 Error
Conveyor Width W1-axis could not start
A state in which the operating command is not normally accepted.
1. Confirm connection to communication cable.
2. Confirm Power supply(24V).
3. Confirm the communication setting of PCI board.
4. Confirm the address of driver and communication rate setting.
EUKYX
3-87199-4100
3.8 Automatic Adjustment
Error ID Error Name, Description, Cause, and Remedy
49 6110 Conveyor Width W1 Error
System setup of Conveyor Width W1 is not completed.
Driver has not completed the parameter setup yet. It is a situation in which a correct setup
has not been received by Communication Error.
Check the Communication Mode, wiring, Power supply of Driver.
49 6111 Conveyor Width W1 Error
Zeroing Error in Conveyor Width W1
LS, discontinuous zeroing movement, was detected.
Check out the dirt, error of sensor and error in Motor body etc.
49 6112 Conveyor Width W1 Error
Out-of-Control in Conveyor Width W1
Motor Out-of-Control which is over the width of Out-of-Control detecting occurred. Please
execute all zeroing again, and the restart production.
Please set motor speed slow if it happens frequently. Also, in a case of structure motor
Error.
49 6113 Conveyor Width W1 Error
Error in Motor Power voltage of Conveyor Width W1
Motor power voltage dropped. Check out the Power supply line(48V Line)
49 6114 Conveyor Width W1 Error
STP input in Conveyor Width W1 was detected
STP input is detected. The function to stop motor by Hard signal.
49 6115 Conveyor Width W1 Error
Over-current in Conveyor Width W1
Error in Motor output line. Check out the motor wiring,
49 6116 Conveyor Width W1 Error
Limit Sensor(+) was detected in Conveyor Width W1.
+LS signal was detected for moving for (+).
Please check the dirt of +LS sensor, disconnection.
49 6117 Conveyor Width W1 Error
Limit Sensor(-) was detected in Conveyor Width W1.
-LS signal was detected for moving for (-).
Please check the dirt of -LS sensor, disconnection.
49 6118 Conveyor Width W1 Error
Motor Disconnection of Conveyor Width W1 was detected.
Disconnection to motor was detected.(Only stop mode)
Check the motor wiring.
49 6119 Conveyor Width W1 Error
Control Power Voltage of Conveyor Width W1 has error
Control power for driver dropped. Check out the Power supply line.(24V Line)
49 611a Conveyor Width W1 Error
-----
Reserved Function of driver. Please make inquiries when error is detected.
49 611b Conveyor Width W1 Error
-----
Reserved Function of driver. Please make inquiries when error is detected.
EUKYX
3-88199-4100
3.8 Automatic Adjustment
Error ID Error Name, Description, Cause, and Remedy
49 611c Conveyor Width W1 Error
-----
Reserved Function of driver. Please make inquiries when error is detected.
49 611d Conveyor Width W1 Error
-----
Reserved Function of driver. Please make inquiries when error is detected.
49 611e Conveyor Width W1 Error
-----
Reserved Function of driver. Please make inquiries when error is detected.
49 611f Conveyor Width W1 Error
System Error in Conveyor Width W1.
System Error of internal driver. Driver error is supposed if this problem happens frequently.
496120 Conveyor Width W1 Error
Communication Error in Conveyor Width W1.
1. Confirm connection to communication cable.
2. Confirm Power supply(24V).
3. Confirm the communication setting of PCI board.
4. Confirm the address of driver and communication rate setting.
496201 Conveyor Width W2 Error
Drive Alarm during Conveyor Width W2 axial operation.
Confirm reset Method of detailed Sub-system error counts of Alarm.
496202 Conveyor Width W2 Error
Conveyor Width W2-axis could not start
A state in which the operating command is not normally accepted.
1. Confirm connection to communication cable.
2. Confirm Power supply(24V).
3. Confirm the communication setting of PCI board.
4. Confirm the address of driver and communication rate setting.
496210 Conveyor Width W2 Error
System setup of Conveyor Width W2 is not completed.
Driver has not completed the parameter setup yet. It is a situation in which a correct setup
has not been received by Communication Error.
Check the Communication Mode, wiring, Power supply of Driver.
49 6 211 Conveyor Width W2 Error
Zeroing Error in Conveyor Width W2
LS, discontinuous zeroing movement, was detected.
Check out the dirt, error of sensor and error in Motor body etc.
496212 Conveyor Width W2 Error
Out-of-Control in Conveyor Width W2
Motor Out-of-Control which is over the width of Out-of-Control detecting occurred. Please
execute all zeroing again, and the restart production.
Please set motor speed slow if it happens frequently. Also, in a case of structure motor
Error.