PCBRM_User_Manual_R9.pdf - 第22页

PCBRM15 & PCBRM System 5.2 User’s Manual Chapter 2: Requirements/Machine Overview Part No. 4005.00.906 2-8 Cleaning Hood (option) Flow Well Heater Control (option) Compliant Arm Locks Preheater X-Rail Handle Flow Wel…

100%1 / 120
PCBRM15 & PCBRM System 5.2 User’s Manual Chapter 2: Requirements/Machine Overview
Part No. 4005.00.906 2-7
Y-Axis Board Lock
X-Axis
Carrier Lock
Z-Axis
Adjustment Wheel
Board
Locks
Carrier Arms
Carrier
Arms
Arm Lock(s)
X-Axis Rail
2.5 PCBRM15 - Carrier Overview
Carrier Arms: Hold board level to solder wave. Adjust to width of board.
X-Axis Carrier Lock: Locks carrier in place once board is aligned over flow well.
Board Locks: Locks board in carrier arms.
Y-Axis Board Lock: Sets y-axis position of board.
Z-Axis Adjustment: Adjusts height of carrier/board in relationship to the flow well.
X-Axis Lock (preheater): Sets x-axis position of carrier/board to flow well.
Arm Lock(s): Lock carrier arms on x-axis rail to hold PCB.
X-Axis Rail: Moves PCB left to right from loading PCB to flow well.
PCBRM15 & PCBRM System 5.2 User’s Manual Chapter 2: Requirements/Machine Overview
Part No. 4005.00.906 2-8
Cleaning Hood (option)
Flow Well
Heater Control (option)
Compliant Arm Locks
Preheater
X-Rail
Handle
Flow Well
Z-Axis
Positioning
Knob
X-Axis Stop
(preheater)
2.6 PCBRM System 5.2 – System Overview
PCBRM15 & PCBRM System 5.2 User’s Manual Chapter 2: Requirements/Machine Overview
Part No. 4005.00.906 2-9
Temperature Monitor Box
E-Stop Switch
Audible Alarm
Type-K
Thermocouple
Temperature
Indicator (PCB)
Power
Receptical
Microswitch
Interface
Receptical
Z-Axis Positioning Knob
Microswitch
Interface Plug
Top
Heater Controls
Bottom
Heater Controls