PCBRM_User_Manual_R9.pdf - 第46页

PCBRM15 & PCBRM System 5. 2 User’s Manual Chapter 4: Process es & Appl icati ons Part No. 4005.00.906 4-4 Main Power Reset Switch Solder Flow Rate Control Hi/Low Flow Wel l Heater Adju st Flow Well Heater Box Spr…

100%1 / 120
PCBRM15 & PCBRM System 5.2 User’s Manual
Chapter 4: Processes & Applications
Part No. 4005.00.906 4-3
A
(B)
Solder Pot
Pump
Solder
1/2”
Solder
Level
Pump Housing
Pump Sleeve
Impeller
The picture can't be displayed.
4 Processes & Applications
4.1 Adding Solder
CAUTION:
USE INSULATED GLOVES WHEN WORKING AROUND HEATED AREA. BE CERTAIN THE MODE
SWITCH IS IN THE OFF POSITION (NEUTRAL POSITION.)
Remove Pot Cover (A).
Insert Baffle Assembly (B) into Pump.
Power up system by depressing main power and reset switch on the PCBRM module.
When the pot reaches 500°F (260°C), place solder bars into pot until solder level is reached.
Using gloves provided, place pot cover back on pot once solder has melted.
Power up preheater panels (for PCBRM Systems only).
PCBRM15 & PCBRM System 5.2 User’s Manual
Chapter 4: Processes & Applications
Part No. 4005.00.906 4-4
Main Power
Reset Switch
Solder Flow Rate Control
Hi/Low Flow Well Heater Adjust
Flow Well Heater Box
Spring Tabs
Screw
1
2
3
4.2 Flow Well Set-Up
Push the Main Power and Reset Switches. Process temperature is factory set at 500˚F (adjust as
required).
Using insulated gloves, push down on flow well and insure it is completely seated on pump. If
required, adjust Spring Tabs of well or tighten Clampable Shank (screw) as required to insure flow
well maintains firmly positioned on pump.
PCBRM15 & PCBRM System 5.2 User’s Manual
Chapter 4: Processes & Applications
Part No. 4005.00.906 4-5
Flow Well
Heater
Heater
Control Box
Note Routing
Of Heater Cable
Connect flow well heaters to power, if applicable. Adjust heaters as required.
Allow machine to reach and stabilize temperaturetypically 45 minutes.
After flow well has heat soaked for 15 minutes, set Solder Flow Rate Control to zero. Mode Switch
and Cycle Machine set to Continuous. Slowly increase Solder Flow Rate Control until solder fills the
flow well and starts flowing over the ends.
Solder may solidify in flow well if not heat soaked. Do not increase flow rate. Allow flow well to
heat soak further.
Select Mode Switch to Off position (center).