PCBRM_User_Manual_R9.pdf - 第88页

Pcbrm15 & PCBRM Syst em 5.2 User ’s Manual Chapter 6: Troubl eshootin g Part No. 4005.00.906 6- 2

100%1 / 120
Pcbrm15 & PCBRM System 5.2 User’s Manual Chapter 6: Troubleshooting
Part No. 4005.00.906 6-1
6: Troubleshooting
6 Troubleshooting .................................................................................................................................. 3
6.0 Air-Vac Technical Service ....................................................................................................................... 3
6.1 Common Problems/Solutions .................................................................................................................. 3
6.2 Temperature Controller Installation (CAL 9900 only) ......................................................................... 5
Pcbrm15 & PCBRM System 5.2 User’s Manual Chapter 6: Troubleshooting
Part No. 4005.00.906 6-2
Pcbrm15 & PCBRM System 5.2 User’s Manual Chapter 6: Troubleshooting
Part No. 4005.00.906 6-3
6 Troubleshooting
6.0 Air-Vac Technical Service
Air-Vac is always willing to assist our customers with any technical or operating questions. If you have
any questions on machine parameters, correct nozzle requirements, options, procedures or
maintenance, please do not hesitate to call.
Air-Vac Engineering Company, Inc.
30 Progress Avenue Seymour, CT 06483 Tel: 203-888-9900 Fax: 203-888-1145
www.air-vac-eng.com
e-mail:
General Sales Information: rework.sales@air-vac-eng.com
Technical Support: rework.tech@air-vac-eng.com
6.1 Common Problems/Solutions
NOTE
ALL PCBRM UNITS ARE TESTED PRIOR TO SHIPPING. TEMPERATURE CONTROLLERS ARE
PROGRAMMED AND TESTED AT 500°F/260°C.
6.1.1 Machine will not turn on, or turns on for a short period and shuts off
1. Defective latching relay 12879.
2. Consult Air-Vac for further help.
6.1.2 Pump Motor will not run
1. Motor fuse blown
WARNING
DO NOT REPLACE MOTOR FUSE WITH ANY OTHER FUSE BESIDES 250V3AG, 3/10 AMP.
INCORRECT FUSING CAN RESULT IN DAMAGE TO SYSTEM. IF MOTOR FUSE STARTS TO BLOW
CONTINUOUSLY, SOLDER PUMP NEEDS TO BE REMOVED, DISASSEMBLED AND THOROUGHLY
CLEANED.
2. Footswitch not plugged in.
3. SP2 activated on temperature controller see 0 #’s 3-5.
4. Stand-by switch activated.
5. Pump seized.
6. Set point temperature set too low solder not molten.
7. Consult Air-Vac for further help.