PCBRM15 & PCBRM System 5.2 User’s Manual Chapter 3: Set Up & Installation Part No. 4005.00.906 3-2

PCBRM15 & PCBRM System 5.2 User’s Manual Chapter 3: Set Up & Installation
Part No. 4005.00.906 3-1
3: Set Up & Installation
3 Set Up & Installation ......................................................................................................................3
3.1 Leveling Module..............................................................................................................................................3
3.2 PCBRM15 – Carrier Arms Installation.......................................................................................................4
3.3 PCBRM System 5.2 - Carrier Arms Installation........................................................................................7
3.4 PCBRM System 5.2 – X Axis Stops, Set Up, Function...............................................................................8
3.5 PCBRM System 5.2 – Z Axis Stop, Set Up, Function ................................................................................9
3.6 PCBRM System 5.2 - Preheater Safety Stop.............................................................................................10
3.7 Optional Fume Extraction Manifold Assembly Installation...................................................................11

PCBRM15 & PCBRM System 5.2 User’s Manual Chapter 3: Set Up & Installation
Part No. 4005.00.906 3-2

PCBRM15 & PCBRM System 5.2 User’s Manual Chapter 3: Set Up & Installation
Part No. 4005.00.906 3-3
3 Set Up & Installation
3.1 Leveling Module
CAUTION:
OPERATION OF THIS MODULE INVOLVES PUMPING OF MOLTEN SOLDER. ALL NORMAL SAFETY
PRACTICES SHOULD BE OBSERVED WITH SPECIAL ATTENTION TO THE FOLLOWING:
SAFETY GLASSES SHOULD BE WORN AT ALL TIMES.
DO NOT MOVE MODULE WHILE SOLDER IS MOLTEN.
DISCONNECT POWER BEFORE SERVICING MODULES.
CAUTION:
LEVELING OF MODULE SHOULD NOT BE ATTEMPTED WITH MOLTEN SOLDER IN THE POT.
Note:
LEVELING IS CRITICAL TO PROVIDE CORRECT SOLDER FLOW.
• Level machine on table.
• Place the level (supplied with tool kit) on Pump Housing (A). Level machine (front to back and
side to side) by adjusting the Leveling Legs.
• After leveling is completed, lock legs with jam nuts.
(A)